/ Electrical connection / Maintenance
The electrical connection must be made in
accordance with applicable standards and
legislation.
Before connecting up the appliance, check that:
•
The mains electricity supply matches the
characteristics indicated on the appliance
data plate.
•
The circuit wiring and outlet are equipped with
a compliant earth connection.
When the oven is connected to the mains power
supply via a socket:
•
Wire a plug onto the power cable which
must comply with applicable standards in the
country of use; the plug (and its fuse, where
applicable) must be suitable for the rated load
specifi ed on the appliance data plate. Connect
the cores of the cable in accordance with the
fi gure, ensuring you follow the harmonised
wiring colour scheme:
L (live/hot/phase) = brown wire
N (neutral) = blue wire
earth ”
” symbol = yellow/green wire
•
The power cable must be positioned in such
a way that it does not reach a temperature of
90°C at any point.
•
Do not use adapters, extension leads, gang
sockets etc. as these could cause loose
contacts and overheat.
When the appliance is to be hard-wired to the
mains circuit:
•
The circuit must be fi tted with a omnipolar
circuit breaker of suitable capacity for the
appliance's rated load.
•
The earth conductor must not be switched
by the breaker and must be connected to the
earthing system.
•
As an alternative, an RCBO may also be used,
or RCD protection in addition to or instead of
a fuse or MCB, depending on the applicable
electrical code.
WARNING: The appliance complies with the
requirements of 2016/426/EU (Gas Appliances
Regulation),
2014/35/EU
(Low
Voltage
Directive) on electrical safety, and 2014/30/EU
(Electromagnetic Compatibility Directive).
REPLACING COMPONENTS
Isolate the appliance’s gas and electricity supplies
before performing any maintenance.
Contact an authorised service centre if functional
components such as burners, taps and electrical
components require replacement.
WARNING:
If the power cable requires replacement, the
installer/maintenance technician must use
H05VV-F 3x0.75 mm
2
cable and leave the earth
conductor around 2 cm longer than the live
and neutral wires. They must also comply with
the instructions given for the initial electrical
connection.
MAINTENANCE
ELECTRICAL CONNECTION
ELECTRICAL CONNECTION
C
EL
EL
N
L