background image

 

17

TABELLE Nr. 2: Anpassung an die verschiedenen Gasarten 
GERÄT DER KATEGORIE:       II2E3B/P (DE)  -  II2H3B/P  (AT) 

Brenner 

Gasart 

Druck 

Ø Düse 

Nominalleistung 

Reduzierte Leistung Ø by-pass

  

  

mbar  1/100mm.

g/h 

l/h 

kW 

kcal/h 

kW 

kcal/h  1/100 mm.

Hilfs-brenner

 

Erdgas

 G20 

20 

77 

95 

860 

0,48 

413 

34 

Erdgas

  G25 

25 

77 

95 

860 

0,48 

413 

34 

Butan  G30 

50 

46 

73 

 - 

860 

0,48 

413 

30 

Propan  G31 

50 

46 

71 

 - 

860 

0,48 

413 

30 

Halb-Schnell

 

Erdgas

 G20 

20 

101 

167 

1,75 

1505 

0,6 

516 

36 

Erdgas

  G25 

25 

101 

167 

1,75 

1505 

0,6 

516 

36 

Butan  G30 

50 

58 

127 

 - 

1,75 

1505 

0,6 

516 

36 

Propan  G31 

50 

58 

125 

 - 

1,75 

1505 

0,6 

516 

36 

Schnell

 

Erdgas

 G20 

20 

129 

286 

2580 

1,05 

903 

52 

Erdgas

  G25 

25 

129 

286 

2580 

1,05 

903 

52 

Butan  G30 

50 

79 

218 

 - 

2580 

1,05 

903 

48 

Propan  G31 

50 

79 

214 

 - 

2580 

1,05 

903 

48 

Dual inner 

Erdgas

 G20 

20 

70 

76 

0,8 

688 

0,48 

413 

34 

Erdgas

  G25 

25 

70 

76 

0,8 

688 

0,48 

413 

34 

Butan  G30 

50 

40 

58 

 - 

0,8 

688 

0,48 

413 

30 

Propan  G31 

50 

40 

57 

 - 

0,8 

688 

0,48 

413 

30 

Dual au

ß

en 

Erdgas

 G20 

20 

2x110 

419 

4,4 

3784 

1,8 

1548 

65 

Erdgas

  G25 

25 

2x110 

419 

4,4 

3784 

1,8 

1548 

65 

Butan  G30 

50 

2x66 

298 

 - 

4,1 

3562 

1,8 

1548 

60 

Propan  G31 

50 

2x66 

293 

 - 

4,1 

3562 

1,8 

1548 

60 

 

 

 

EINSTELLUNG DER BRENNER: 

 

Einstellung des "MINIMUMS" der Brenner 

 

Um die Minimumeinstellung der Brenner vorzunehmen, wie im Folgenden angegeben vorgehen:

 

1)  Den Brenner anzünden und den Drehknopf auf die Position MINIMUM stellen (kleine Flamme). 
2)  Den Drehknopf des Hahnes, der durch einfachen Druck auf der Stange desselben befestigt ist, entfernen (Fig. 11). 
3)  Einen kleinen Schraubenzieher seitlich von der Stange des Hahnes der Arbeitsfläche in Übereinstimmung mit der (goldenen) 

Schraube, die sich im unteren Teil des Hahnes (Fig. 11) befindet, verwenden und die Drosselschraube nach rechts oder links 
drehen, bis die Flamme des Brenners richtig auf das MINIMUM eingestellt ist. 

4)  Sich dessen versichern, das die Flamme beim schnellen Übergang von der Position MAXIMUM zur Position MINIMUM nicht 

ausgeht. 

ACHTUNG: Die obengenannte Einstellung wird nur bei mit Erdgas oder Stadtgas (wo vorgesehen) betriebenen Brennern 
vorgenommen, während bei mit Flüssiggas betriebenen Brennern die Schraube im Uhrzeigersinn fest angezogen werden 
muss. 

 

ELEKTRISCHER ANSCHLUSS DES GERÄTES: 

Der elektrische Anschluß muss entsprechend den Bestimmungen und Verfügungen der geltenden Gesetze durchgeführt 
werden.

 

Vor Durchführen des Anschlusses überprüfen, daß: 
 -  Die elektrische Leistung der Anlage und der Steckdosen der maximalen Leistung des Gerätes entspricht. (siehe Hinweisetikett im 

unteren Teil des Gehäuses). 

Die Steckdose oder die Anlage mit einer wirksamen Erdungsverbindung nach den Bestimmungen und Verfügungen des momentan 
geltenden Gesetzes versehen sind. Es wird jede Haftung für die Nichtbeachtung dieser Verfügungen abgelehnt. 

Wenn die Verbindung an das Speisungsnetz mit Steckdose durchgeführt wird: 

 - Auf das Speisungskabel (wenn nicht vorhanden) einen genormten Stecker aufbringen, der für die auf dem Hinweisetikett angegebene 

Last geeignet ist. Die Kabel nach dem Schaltplan der Fig. 12 anschließen und dabei die unten aufgeführten Entsprechungen 
beachten: 

  Buchstabe L (Phase) = braunes Kabel; 
  Buchstabe N (Nulleiter) = blaues Kabel; 

  Symbol”

” 

Erde = gelb-grünes Kabel; 

Das Speisungskabel muss so positioniert sein, daß es nirgendwo eine Übertemperatur von 75 K erreicht. 

-  Für die Verbindung keine Reduktionen, Adapter oder Nebenschlüsse verwenden, da sie falsche Kontakte mit daraus folgenden 

gefährlichen Überhitzungen provozieren könnten. 

Wenn die Verbindung direkt an das Stromnetz durchgeführt wird: 

Zwischen das Gerät und das Netz einen einpoligen Schalter setzen, der der Last des Gerätes entspricht, mit Mindestöffnung   

zwischen  den Kontakten von 3 mm. 

Daran denken, daß das Erdungskabel nicht vom Schalter unterbrochen werden darf.  

In Alternative dazu kann die elektrische Verbindung auch durch einen hochsensiblen Differentialschalter geschützt sein. 

Es wird dringend empfohlen, das entsprechende gelb-grüne Erdungskabel an eine wirksame Erdungsanlage anzuschließen. 

 

ACHTUNG: Das Gerät erfüllt die Vorschriften der EWG-Richtlinien 90/396 (Gasrichtlinie) für Gasherde für den Hausgebrauch und Ähnliches, 
93/68 und 73/23 (Niedrigspannungsrichtlinie) für die elektrische Sicherheit und 2004/108/EG, 93/68 und 89/336 (EMC-Richtlinien) für die 
elektromagnetische Kompatibilität; 
 

 

Summary of Contents for P92

Page 1: ...O P92 P92V FR BE INSTRUCTIONS POUR L INSTALLATION L ENTRETIEN ET page 11 L UTILISATION DES TABLES DE CUISSON ENCASTRABLES 91 5X64 cm TIPO P92 P92V DE AT MONTAGE WARTUNGS UND GEBRAUCHSANWEISUNGEN seite 15 FÜR EINBAUKOCHFLÄCHEN MIT GASBETRIEB UND GEMISCHTEM BETRIEB 91 5X64 cm TIPO P92 P92V NL INSTRUCTIES VOOR DE INSTALLATIE HET ONDERHOUD EN pag 20 HET GEBRUIK VAN GAS EN GEMENGDE INBOUWKOOKVLAKKEN 91...

Page 2: ...il riciclaggio degli apparecchi dismessi valide su tutto il territorio dell Unione Europea MANUALE TECNICO PER L INSTALLATORE NOTIZIE PER L INSTALLATORE L installazione tutte le regolazioni le trasformazioni e le manutenzioni elencate in questa parte devono essere eseguite esclusivamente da personale qualificato legge n 46 e D P R 447 Un errata installazione può causare danni a persone animali o c...

Page 3: ...utilizzando le viti fornite con il corredo dell alzatina fig 8 ALLACCIAMENTO DELL APPARECCHIO ALLA RETE GAS Prima di procedere all allacciamento dell apparecchio alla rete gas occorre innanzitutto togliere il tappo di protezione in plastica del circuito gas che e inserito a pressione nel raccordo di entrata dello stesso per rimuoverlo basta semplicemente sfilarlo Accertarsi quindi che i dati dell ...

Page 4: ... la fiamma non si spenga ATTENZIONE La regolazione suddetta va eseguita soltanto con bruciatori funzionanti a gas metano mentre con bruciatori funzionanti a gas liquido la vite deve essere bloccata a fondo in senso orario ALLACCIAMENTO ELETTRICO DELL APPARECCHIO Il collegamento elettrico deve essere eseguito in conformità con le norme e le disposizioni di legge in vigore Prima di effettuare l alla...

Page 5: ...mensioni piano cottura Tipo di piano cottura Tipo i e sezione cavo di alimentazione 91 5x64 cm bruciatori gas H05VV F 3x0 75 mm2 ATTENZIONE Nel caso di sostituzione del cavo di alimentazione l installatore dovrà tenere il conduttore di terra più lungorispetto ai conduttori di fase di circa 2 cm ed inoltre dovrà rispettare le avvertenze riguardanti l allacciamento elettrico Ingrassaggio dei rubinet...

Page 6: ...iammiferi L accensione dei bruciatori con termocoppie di sicurezza può avvenire solamente quando la manopola è sulla posizione di MASSIMO fiamma grande Durante la cottura di cibi con olio e grasso facilmente infiammabili l utilizzatore non deve allontanarsi dall apparecchio Non utilizzare spray in prossimità dell apparecchio quando è in funzione Durante l uso dei bruciatori assicurarsi che le mani...

Page 7: ... NON PROFESSIONAL USE IN HOUSEHOLDS This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This guideline is the frame of a European wide validity of return and recycling on Waste Electrical and Electronic Equipment TECHNICAL MANUAL FOR THE INSTALLER INFORMATION FOR THE INSTALLER The installation all regulations changes and mainten...

Page 8: ...t part of the backguard and fix them with a screws supplied with the backguard kit fig 8 CONNECTING THE APPLIANCE TO THE GAS SUPPLY Before connecting the appliance to the gas supply you first need to remove the plastic protective plug for the gas supply which is inserted under pressure in the gas inlet connection To remove the plug simply unscrew it Then make sure that the details shown on the lab...

Page 9: ...ply The switch must be of a suitable charge for the appliance with a minimum opening between the contacts of 3 mm Remember that the earth wire must not be interrupted by the switch Alternatively the electrical connection can also be protected by a differential switch of high sensitivity You are strongly advised to fix the special yellow green earth wire to an efficient earthing system ATTENTION Th...

Page 10: ... there is no electric current you can light the burners with matches Lighting the burners with safety thermocouples can only be carried out when the knob is on MAXIMUM large flame When cooking food with oil or fat which can easily set alight the user must not leave the appliance Do not use sprays near the appliance when it is in use When using the burners make sure that the pan handles are in the ...

Page 11: ... récupération des appareils usagés applicables dans les pays de la CE NOTICE TECHNIQUE DESTINEE A L INSTALLATEUR INFORMATIONS DESTINEES A L INSTALLATEUR L installation les réglages les transformations et les opérations d entretien décrits dans cette section doivent être exclusivement effectués par un personnel qualifié Une mauvaise installation peut provoquer des dégâts à des personnes animaux ou ...

Page 12: ... suffit simplement de le dévisser Vérifiez si les données reportées sur la plaquette d identification appliquée au bas du caisson sont compatibles avec celles du réseau de distribution du gaz La plaquette appliquée sur la dernière page de cette notice et au bas du caisson reporte les conditions de réglage de la table le type de gaz et la pression d exercice IMPORTANT La table doit être installée c...

Page 13: ...le avec une ouverture minimale entre les contacts de 3 mm Rappelez vous que le câble de terre ne doit pas être interrompu par l interrupteur En alternative le branchement électrique peut aussi être protégé avec un interrupteur différentiel à haute sensibilité Il est vivement recommandé de relier le fil de terre jaune vert à une mise à la terre efficace ATTENTION l appareil est conforme aux prescri...

Page 14: ...lisez toujours des récipients à fond plat ATTENTION En cas de coupure de courant les brûleurs peuvent être allumés avec des allumettes L allumage des brûleurs avec thermocouple de sécurité n est possible que si la manette est sur la position de MAXIMUM grande flamme Pendant la cuisson d aliments avec de l huile ou de la graisse facilement inflammables l utilisateur ne doit pas s éloigner de la tab...

Page 15: ...e in diesem Teil aufgelisteten Einstellungen Veränderungen und Wartungsarbeiten dürfen nur von qualifiziertem Personal ausgeführt werden Eine unkorrekte Montage kann Schäden an Personen Tieren und Sachen verursachen für die der Hersteller nicht haftbar gemacht werden kann Die Sicherheitsvorrichtungen oder diejenigen der automatischen Einstellung der Geräte können die ganze Lebensdauer der Anlage ü...

Page 16: ...et werden EINRICHTUNGSINSTRUKTIONEN DES WANDPFEILERS Achten darauf die Sequenz der nachstehenden Einrichtungsinstruktionen zu respektieren 1 Nehmen Sie die 2 Befestigungsschrauben des Kochplans gemäß den Hinweisen des Bild 5 weg 2 setzen den Teil vor Wandpfeiler und befestigen durch den Boden mittels der 2 Schrauben die weggenommen Punkt 2 nach Hinweisen von Abb Bild 6 3 den früheren Teil des Wand...

Page 17: ...ommen während bei mit Flüssiggas betriebenen Brennern die Schraube im Uhrzeigersinn fest angezogen werden muss ELEKTRISCHER ANSCHLUSS DES GERÄTES Der elektrische Anschluß muss entsprechend den Bestimmungen und Verfügungen der geltenden Gesetze durchgeführt werden Vor Durchführen des Anschlusses überprüfen daß Die elektrische Leistung der Anlage und der Steckdosen der maximalen Leistung des Gerätes...

Page 18: ... Ø 95 Dual Ø 140 BESCHREIBUNG SCHALTTAFEL Auf der Schalttafel wird in Übereinstimmung jeden Drehgriffs oder Taste mit einem kleinen Symbol die Funktion sichtbar gemacht Folgend sind die verschiedene Schaltungen die sich auf einem Küchenherd befinden können aufgelistet Das Symbol zeigt die Anordnung der Brenner auf der Arbeitsfläche der volle Kreis steht für die Erkennung des in Betrieb befindliche...

Page 19: ...amere Belüftung durch Erhöhen der mechanischen Saugleistung wenn es sie gibt REINIGUNG DES GERÄTES Vor jedem Reinigungsvorgang das Gerät vom Stromversorgungsnetz abschalten und den Haupthahn für die Zuführung von Gas zum Gerät schließen Reinigung der Arbeitsfläche Die Brennerköpfe die Grills aus lackiertem Stahl die lackierten Deckelchen und die Flammenteiler müssen regelmäßig mit lauwarmer Seifen...

Page 20: ...FESSIONEEL GEBRUIK Dit apparaat is voorzien van een merkteken zoals bedoeld in de Europese Richtlijn 2002 95 EG Dit apparaat is voorzien van een merkteken zoals bedoeld in de Europese Richtlijn 2002 96 EG betreffende afgedankte elektrische en elektronische apparatuur AEEA Deze richtlijn legt de bepalingen vast voor de inzameling en de recycling van afgedankte apparatuur die op heel het grondgebied...

Page 21: ... of rechtstreeks met de buitenkant verbonden kappen zie fig 3 Indien geen kap geplaatst kan worden is het gebruik van een ventilator geïnstalleerd op een venster of rechtstreeks met de buitenkant verbonden toegestaan de ventilator moet tezamen met het apparaat in werking gesteld worden zie fig 4 mits de nationale normen inzake de ventilatie van de lokalen in acht genomen zijn INSTALLATIE VAN DE PL...

Page 22: ...g naar rechts gedraaid en geblokkeerd moet worden ELEKTRISCHE AANSLUITING VAN HET APPARAAT De elektrische aansluiting moet verricht worden met inachtneming van de bestaande normen en wetsbepalingen Alvorens tot de elektrische aansluiting over te gaan controleer of het elektrisch draagvermogen van de installatie en van het stopcontact passend is bij het maximum vermogen van het apparaat zie het typ...

Page 23: ... 70 Snel Ø 95 Vlamkroon Ø 130 BESCHRIJVING BEDIENINGSPANEEL BESCHRIJVING VAN HET BEDIENINGSPANEEL Op het bedieningspaneel wordt overeenkomstig elke draaiknop of toets de functie weergegeven door middel van een klein symbool Vervolgens worden de verschillende bedieningen aangeduid die u kan vinden op een fornuis het symbool duidt de schikking van de branders op het werkvlak aan het gevulde bolletje...

Page 24: ...nde ventilatie nodig maken bv het openen van een raam of een meer efficiënte ventilatie door vermeerdering van het vermogen van de mechanische opzuiginrichting indien deze bestaat SCHOONMAAK VAN HET APPARAAT Alvorens over te gaan tot schoonmaak van het apparaat trek de stekker uit het stopcontact en sluit de algemene gaskraan Schoonmaak van het werkvlak maak de brandershoofden de geëmailleerde sta...

Page 25: ...25 Fig 1 Fig 2 Fig 3 Fig 4 ...

Page 26: ...26 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 ...

Page 27: ...27 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 ...

Page 28: ...28 Cod 310518 ...

Reviews: