background image

 

9

INSTALLATION

 

ADJACENT

 

TO

 

KITCHEN

 

CABINETS

 

WARNING

 

To

 

eliminate

 

the

 

risk

 

of

 

burns

 

or

 

fire

 

by

 

reaching

 

over

 

heated

 

surface

 

units,

 

cabinet

 

storage

 

space

 

located

 

above

 

the

 

surface

 

units

 

should

 

be

 

avoided.

 

If

 

cabinet

 

storage

 

is

 

to

 

be

 

provided,

 

the

 

risk

 

can

 

be

 

reduced

 

by

 

installing

 

a

 

range

 

hood

 

that

 

projects

 

horizontally

 

a

 

minimum

 

of

 

5

 

inches

 

beyond

 

the

 

bottom

 

of

 

the

 

cabinets.

 

 

This

 

range

 

may

 

be

 

installed

 

directly

 

adjacent

 

to

 

existing

 

countertop

 

high

 

cabinets

 

(36"

 

or

 

91.5

 

cm

 

from

 

the

 

floor).

  

For

 

the

 

best

 

look,

 

the

 

worktop

 

should

 

be

 

level

 

with

 

the

 

cabinet

 

countertop.

 

This

 

can

 

be

 

accomplished

 

by

 

raising

 

the

 

unit

 

using

 

the

 

adjustment

 

spindles

 

on

 

the

 

legs.

 

ATTENTION:

 

the

 

range

 

CANNOT

 

be

 

installed

 

directly

 

adjacent

 

to

 

kitchen

 

walls,

 

tall

 

cabinets,

 

tall

 

appliances,

 

or

 

other

 

vertical

 

surfaces

 

above

 

36"

 

(91.4

 

cm)

 

high.

 

The

 

minimum

 

side

 

clearance

 

in

 

such

 

cases

 

is

 

6"

 

(15.2

 

cm).

 

Wall

 

cabinets

 

with

 

minimum

 

side

 

clearance

 

must

 

be

 

installed

 

18"

 

(45.7

 

cm)

 

above

 

the

 

countertop

 

with

 

countertop

 

height

 

between

 

35

 

½”

 

(90.2

 

cm)

 

and

 

37

 

¼”

 

(94.6

 

cm).

 

The

 

maximum

 

depth

 

of

 

wall

 

cabinets

 

above

 

the

 

range

 

shall

 

be

 

13"

 

(33.0

 

cm)

  

 

 

 

 

 

EXHAUST

 

HOOD

 

INSTALLATION

 

This

 

range

 

will

 

best

 

perform

 

when

 

used

 

with

 

PRO

 

line

 

Bertazzoni

 

exhaust

 

hoods.

 

These

 

hoods

 

have

 

been

 

designed

 

to

 

work

 

in

 

conjunction

 

with

 

the

 

Bertazzoni

 

range

 

and

 

have

 

the

 

same

 

finish

 

for

 

a

 

perfect

 

look.

  

For

 

maximum

 

performance,

 

the

 

height

 

of

 

the

 

bottom

 

of

 

the

 

hood

 

from

 

the

 

worktop

 

should

 

be

 

between

 

25

 

1/2"

 

(65

 

cm)

 

and

 

31

 

1/2"

 

(80

 

cm).

 

This

 

would

 

typically

 

result

 

in

 

the

 

bottom

 

of

 

the

 

hood

 

being

 

61

 

1/2"

 

(156.2

 

cm)

 

to

 

67

 

1/2"

 

(171.5

 

cm)

 

above

 

the

 

floor.

 

These

 

measurements

 

provide

 

for

 

safe

 

and

 

efficient

 

operation

 

of

 

the

 

hood.

 

Before

 

installation

 

of

 

the

 

exhaust

 

hood,

 

consult

 

local

 

or

 

regional

 

building

 

and

 

installation

 

codes

 

for

 

additional

 

specific

 

clearance

 

requirements.

  

Refer

 

to

 

the

 

range

 

hood

 

installation

 

instructions

 

provided

 

by

 

the

 

manufacturer

 

for

 

additional

 

information.

  

 

      

 

 

30” (76,2 cm) 

36” (91,5 cm) 

13” (33,0 cm) 

18” (45,7 cm) 

35”1/2(90,2 cm) /  

37” ¼ (94,6 cm)

 

  6” (15,2 cm) 

Summary of Contents for MAS304INSXT

Page 1: ...lent at cooking delicious recipes for yourself your family and your friends we try our best to make cooking easier more effective and more fun Our appliances are designed according to the strictest safety and performance standard for the European and the North American market We follow the most advanced manufacturing philosophy Each appliance leaves the factory after thorough quality inspection an...

Page 2: ...y be used with the appliance in each case it shall be installed in conformity with the appropriate national and local standards Exhaust hood operation may affect other vented appliances in each case it shall be installed in conformity with the appropriate national and local standards INSTALLING THE LEGS Bertazzoni ranges must be used only with the legs properly installed Four height adjustable leg...

Page 3: ...ve n 2 screws fixing worktop as shown below Place front part of the backguard and attach it from bottom side with the two removed screw point 2 as shown below Fix the front part of the backguard with the screws supplied with the backguard kit Assemble back part with front part of the backguard and fix them with a screws supplied with the backguard kit ...

Page 4: ...t the desired height plus 1 8 0 32 cm The brackets must be placed at 2 5 16 6 0 cm from the side of the range The distance between the two bracket is 25 1 4 64 1 cm Secure the brackets to the wall with appropriate hardware Slide the range against the wall until the brackets are fully inserted into their receptacles on the back of the range INSTALLATION REQUIREMENTS ELECTRICAL A properly grounded a...

Page 5: ...imum side clearance must be installed 18 45 7 cm above the countertop with countertop height between 35 90 2 cm and 37 94 6 cm The maximum depth of wall cabinets above the range shall be 13 33 0 cm EXHAUST HOOD INSTALLATION This range will best perform when used with PRO line Bertazzoni exhaust hoods These hoods have been designed to work in conjunction with the Bertazzoni range and have the same ...

Page 6: ... Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL WHITE electrical supply wire Connect the GROUND receptacle terminal to the incoming GROUND GREEN electrical supply wire OPTION 2 THREE Wires connection Connect the L1 receptacle terminal to the incoming BLACK electrical supply wire L1 hot wire Connect the L2 receptacle terminal to the incoming RED electrical supply wire L2 hot wire C...

Page 7: ...hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug WARNING ELECTRICAL SHOCK HAZARD Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance Provide appropriate ground for the appliance Use copper conductors only Failure to follow these instructions could result in serious injury...

Page 8: ...number of your range It is located under the front edge of the range cooktop and is visible when the oven door is open see illustration A Rating plate s located under front edge of cooktop B Wiring schematic diagram placed on backside panel and on installation booklet WIRING DIAGRAM ...

Page 9: ... stainless steel cleanser If build up occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel Scratches are almost impossible to remove Before using the...