background image

 

Electrical connection

 

The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the 
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is 
about 1W for 5 gas burner version or 2W for 6 gas burners version. 

WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) 
grounding plug for your protection against shock hazard and should be plugged directly into a 
properly grounded receptable. Do not cut or remove the grounding prong from this plug.   

 

Wiring diagrams

    

 

 

 

Wiring diagram description  

see Fig. 12.  

 

 

 

 

 

1. Cable terminal 

 

 

 

 

 

 

 

2. Ignition switch 
3. Spark generator 
4. Ignition spark 
L. Black 
N. White 
T. Green (earth) 

 
Room ventilation – Location and venting. 

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 

Conversion to different types of gas 

Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 

To change the nozzles of the burners  use the following procedure: 

 

Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 

 
TABLE A: Adapting to different types of gas     

Burner

 

Position 

Inj. size

 

Gas 

Pressure 

Max Rate 

Min Rate 

By-pass size 

 

 

1/100mm 

Type 

[i.w.c.] 

[BTU/h] 

[W] 

[BTU/h] 

[W] 

[1/100mm] 

Auxiliary

 

Front R 

92 

NG 

4” 

3750 

1098 

900 

264 

Regulated 

 

 

56 

LP(Propane) 

11” 

3750 

1098 

900 

264 

29 

Semi-Rapid

 

Rear L 

117 

NG 

4” 

6000 

1759 

1500 

439 

Regulated 

 

 

73 

LP(Propane) 

11” 

6300 

1845 

1500 

439 

36 

Rapid

 

Rear R 

155 

NG 

4” 

10400 

2046 

2500 

732 

Regulated 

 

 

98 

LP(Propane) 

11” 

11400 

3339 

2500 

732 

47 

 

Front L Inner 

80 

NG 

4” 

 

 

900 

264 

Regulated 

Dual 

 

50 

LP(Propane) 

11” 

NG   17000 

4980 

29 

burner 

Front L Outer 

N°2 x 130 

NG 

4” 

LP    18800 

5507 

Regulated 

 

 

N°2 x 83 

LP(Propane) 

11” 

 

 

65 

CAUTION: save the orifices removed from the appliance for future use  

Regulation of burners 

Regulation of the "MINIMUM" on the burners 

To regulate the minimum on the burners carry out the following procedure indicated below: 
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ). 
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of 
the tap itself. 
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower 
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until 
the flame of the burner is regulated in the most suitable way to MINIMUM. 
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the 
MINIMUM position.  

ATTENTION: The regulation described above can be carried out only with burners using natural gas, 
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.   

Summary of Contents for B7G0 A7X Series

Page 1: ...iance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppliers call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Read this instruction booklet before installing and usin...

Page 2: ... when moving the cooktop The pressure regulator has female pipe thread You will need to determine the fitting required depending on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 The appliance ...

Page 3: ...rner of the cooking appliance and the range hood be less than 25 1 2 650mm Any other downward facing combustible surface less than 600mm above the top of the highest burner shall be protected for the full width and depth of the cooking surface area However in no case shall this clearance to any surface be less than 173 4 450mm Maximum depth for the overheads cabinet is 13 330mm 2 Side clearances M...

Page 4: ...as supply and making all connections check thoroughly for possible leaks Turn all control knobs on the unit to OFF position Open the valve on the gas supply Using a soap and water solution check each gas connection one at the time by brushing the solution over the connection Presence of bubbles will indicate a leak Tighten the fitting and re check for leaks If it is not possible to correct the lea...

Page 5: ...zles with those designed for the new gas supply according to the information given in TABLE A shown below TABLE A Adapting to different types of gas Burner Position Inj size Gas Pressure Max Rate Min Rate By pass size 1 100mm Type i w c BTU h W BTU h W 1 100mm Auxiliary Front R 92 NG 4 3750 1098 900 264 Regulated 56 LP Propane 11 3750 1098 900 264 29 Semi Rapid Rear L 117 NG 4 6000 1759 1500 439 R...

Page 6: ...l Burner 2 Medium burner 3 Rapid burner 4 Dual burner 5 Front right side burner control knob 6 Front left side burner control knob 7 Rear left side burner control knob 8 Rear right side burner control knob Service maintenance instructions Service and maintenance only to be carried out by an authorised person To replace parts such as burners valves and electric components the hotplate must be remov...

Page 7: ...arge flame and then press the knob down to activate the spark ignition Once ignited keep pressing the knob for about 10 seconds to allow the flame to heat the thermocouple If the burner does not remain alight after releasing the knob repeat the above procedure Use of the Dual burner Fig 14 This model controls both the central and the external crown of the burner with just one valve To ignite the c...

Page 8: ... be disconnected from the power supply Cleaning the work surface periodically clean the burner heads the enamelled steel pan supports and the burner caps using warm water Any spillage must always be removed as soon as possible using a rag If it become difficult to open or close a valve do not force it but immediately request the assistance of the technical service personnel Cleaning the enamelled ...

Page 9: ...chez aucun interrupteur électrique N utilisez aucun téléphone dans votre établissement Appelez immédiatement votre fournisseur de gaz par le téléphone d un voisin Suivez les instructions du fournisseur de gaz Si vous ne pouvez pas atteindre vos fournisseurs de gaz appelez les pompiers L installation et le service doivent être exécutés par un installateur qualifié une agence de service ou par le fo...

Page 10: ...GA de 1 5 mètres de longueur maximum I D recommandé pour le branchement de cette table de cuisson au conduit d amenée des gaz Ne pliez pas ou n endommagez pas le connecteur flexible en déplaçant la table de cuisson Le régulateur de pression a un filetage au pas du gaz femelle de Vous devrez déterminer le raccordement demandé selon la dimension du conduit d amenée des gaz du connecteur en métal fle...

Page 11: ... 1 2 Exigences 1 Distances des meubles suspendus Valeurs minimum Les distances minimum devront être conformes aux valeurs minimum indiquées dans la table n 1 et sont illustrées dans la fig 1 2 Les hottes de cuisine et les ventilateurs aspirant doivent être installés selon les instructions du fabricant Cependant dans aucun cas la distance entre la partie supérieure du brûleur le plus haut de l appa...

Page 12: ...VEC UNE CLE LORSQU ON BRANCHE L ALIMENTATION NE PAS SERRER La pression réglée pour GN est de 4 colonne d eau Voir Fig 5 6 Pour la position d entrée du gaz de l appareil référez vous à la Fig 5 6 et 7 Après avoir installé l alimentation du gaz et après avoir effectué tous les branchements contrôlez soigneusement les éventuelles fuites Tournez tous les boutons de commande de l unité sur la position ...

Page 13: ...ns le meme local en chaque cas elle doit etre eventuellement installée conformement aux normes nationals en vigueur Conversion à différents types de gaz Avant d effectuer n importe quel travail d entretien débranchez l appareil de l alimentation gaz et électrique Pour le Gaz Naturel utilisez le régulateur illustré en Fig 5 Pour LP Gaz utilisez celui illustré en Fig 5 REMPLACEMENT DES BECS POUR L U...

Page 14: ...ession du type convertible pour l utilisation avec Gaz Naturel à une pression de sortie nominale de 4 w c colonne d eau ou LP gaz à une pression de sortie nominale de 11 w c colonne d eau et il est prédisposé par l usine pour fonctionner avec un de ces gaz pression comme indiqué sur les étiquettes de réglage apposées sur l appareil l emballage et le livret d instructions Pour convertir le régulate...

Page 15: ... l unité Pour le positionnement de la prise au mur pour le branchement de la bonde de mise à terre à trois pôles de l appareil voir les indications illustrées en Fig 1 2 ATTENTION Après la première installation de l appareil ou après n importe quelle intervention d entretien concernant les parties principales du gaz de l appareil effectuez le test de fuite en utilisant de l eau avec du savon sur l...

Page 16: ...tte sur la position 3 on a la couronne interne au maximum et la couronne externe éteinte En tournant la manette sur la position 4 on a la couronne interne au minimum et la couronne externe éteinte Avertissement Il est recommandé de ne pas essayer d allumer le brûleur si le chapeau de la flamme relative n est pas en position correcte Suggestions pour une utilisation correcte des brûleurs ATTENTION ...

Page 17: ...lées devront être nettoyées fréquemment avec de l eau savonneuse N utilisez pas de poudres abrasives Ne laissez pas de substances acides ou alcalines sur les parties émaillées comme par exemple du vinaigre jus de citron sel sauce tomate etc et ne lavez pas les parties émaillées lorsqu elles sont encore chaudes Nettoyage des parties en acier inox Nettoyez les parties avec de l eau savonneuse et séc...

Page 18: ...18 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Page 19: ...19 Fig 7 Fig 8 Fig 9 Fig 10 Inches mm A 1 11 16 43 B 1 3 16 30 C 1 1 16 27 E 4 7 16 112 ...

Page 20: ...20 Fig 11 Fig 12 Fig 14 Fig 15 ...

Reviews: