Concealed system 805S
File a chamfer (chamfered edge) against the trimmed
surfaces of the two sockets.
Silicone oil on the seals makes
assembly easier.
1. In order to be able to clearly mark the distances of your markings, first glue some masking tape lengthwise onto
the connecting pipes. Insert these into the module and mark both flush with the front. Then place the tubes in the
ceramic and mark them as well.
3. The edges are slightly inclined (about 45 °).
This will prevent seals from being damaged during later insertion.
u
w
a
2a. You receive the difference amounts
L
1
for the inflow and
L
2
for the outflow.
2b. To ensure a stress-free installation, add to the inlet
L
1
+ 6mm and the drain
L
2
+ 3mm.
Transfer each of these short dimensions to the ends of the pipes in the direction of the ceramic connection.
You can now shorten both connecting pipes with a saw.
v
b
v
a
w
b