18
ANGLEMASTER • AM3000DX
© Bernhard and Company Limited
6.1
USE A QUALIFIED ELECTRICIAN
6.1.1 In the event of any motor not starting / magnets not working, the following procedure
should be adopted.
6.1.2 Check voltage at PWR Plug to Control PCB in the electrical drawer.
6.1.3 Check main fuses/breakers feeding machine if voltage is not normal - also check
individually labelled fuses on Control PCB.
6.1.4 Check that
EMERGENCY STOP BUTTON
on control pendant is not locked in
STOP
position.
6.1.5 Check for open circuit on overload terminals 95 and 96, press overload reset button to
correct.
6.1.6 Check that reset button on clear control box lid is not permanently in contact with red
button on overload. Adjust as required.
6.1.7 Listen for the functioning of all contactors/relays in the control box by operating the
individual motor control buttons, and the reversing microswitch.
6.1.8 If the relevant contactor is operating correctly check the voltage on the out going contactor
terminals and then the voltage at the appropriate motor terminals.
6. Electrical Fault Finding