Installation pre-conditions
The inductiongerät must be mounted in a straight surface by means of a mounting frame. The
air supply and outlet area must not be obscured. The installation area must allow a weight of
at least 100 kg. The mains disconnector must be easily accessible.
Installation regulations for the installation model
The following points must be observed:
-
Check and make sure that the voltage of the main supply line matches that of the type plate.
-
The electrical installations must comply with local building installation regulations. The
applicable national regulations of the electricity authorities must be complied with.
-
The inductiongerät is equipped with a power cable, which can be connected to a socket with
the necessary plug.
-
If incorrect current circuit breakers are used, they must be designed for a fault current of at
least I n=30mA.
-
Prevent blocking of the air supply and air outlet zone by objects (fabric, wall, etc.)
-
Avoid that hot ambient air is sucked in by the inductiongerät (several devices stand side by
side, devices stand one after the other, near frying tippers or ovens). Otherwise, a duct must
be used.
-
The device has a suction filter. Nevertheless, you must ensure that no fat ambient air caused
by other applications can be sucked into the induction device (near fryers, grill plates or
fryers).
-
The air intake temperature must be below +35°C.
-
Operators must ensure that all installation, maintenance and inspection work is carried out
by approved personnel.
-
The intake air must be channelled and fed directly to the fans via the supplied filter. The
intake cross-section should be at least 200 cm2 per electronic unit.
-
Do not build a thermal short circuit. The exhaust air must not be sucked back in, otherwise
the device will become hotter and hotter.
-
The installation must be checked for practicality. For this purpose, the maximum cooling
plate temperature must be determined. Measurements are made on the cooling plate base
plate below the induction coil. The temperature must not exceed 65°C in continuous
operation of at least 2 hours and 20°C ambient temperature.
-
All INSTALLATION models must be fastened by means of an enclosed mounting frame.
-
The power supply cable must be shielded in general and contacted cleanly on both sides.
-
Provide the mains disconnector in such a way that a maximum of 5 times per day is switched
on and off.
-
To maintain and replace parts, the device must be disconnected from the power supply. If a
pull of the plug is provided, clearly pointing out that the pulling of the plug must be done in
such a way that the operator can check from any seat to which it has access that the plug
is still removed. If this is not possible due to the design of the device or the installation, the
separation must be ensured with a locking in the separation position.
The inductiondevices areequipped with a cable and plug in accordance with national
regulations.
Make sure the plug is wired correctly:
For the electrical connection of the device, the legal
Regulations of the respective country!
attention
Incorrect voltage can cause the
Damage induction device
attention
The electrical connections must be carried
out by a specialist.
Summary of Contents for BGI40
Page 19: ...side 18 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Page 22: ...side 21 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 manager...
Page 24: ...side 23 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Page 25: ...side 24 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 BIPDS Generators...
Page 26: ...side 25 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...