Overview Error messages on display
Short-circuit temperature sensor plate, plate temperature too low (smaller -50°C)
(every 5 sec when switched off)
Temperature plate too high, interruption temperature sensor on the plate >
260°C
No pan on the plate (too small pan on the plate)
Incorrect pan on the plate, short-circuit induction coil (a value to low)
Heat sink temperature >100°C or temperature sensor cooling plate short-
circuited
Heat sink temperature <-15°C or temperature sensor cooling plate interrupted
Missing or defective potentiometer: Incorrect value (greater than 10.75 kOhm)
Potentiometer to 0 position, residual heat indicator Hob temperature >45°C
signal for external display is missing (external display is set or SW1/3 switched
on)
or
Temperature plate too high, interruption temperature sensor on the plate >
260°C
Switching on after power disconnection AC Phase L1 and L3 against zero < 150V
(If L2 fails, device with reduced power continues to run)
Failure of standard IO DEVICE 1 or 2 (possibly display print defective)
Warning: DC current greater than 350 mA (too many or incorrect fans)
Warning: Fan not connected or blocked (after start 5 sec, then every 10 sec for 1
sec.)
Overcurrent on induction coil, then 10 sec. pause. Device
Off
and Back
On
Switch On
Summary of Contents for BGI40
Page 19: ...side 18 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Page 22: ...side 21 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 manager...
Page 24: ...side 23 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Page 25: ...side 24 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 BIPDS Generators...
Page 26: ...side 25 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...