4.5
LED
(C)
The white LED light up upon starting the pressing process (up to about 30 sec. after the end of
the pressing process).
The LED lights up green:
the pressing process can be executed..
- lights up red:
the rechargeable battery is discharged; charge the rechargeable battery in the
charging station.
- flashes red:
after 40,000 pressing processes the LED flashes after every pressing process as
an indication of the need for the next inspection. An internal counter stores the number of press-
ings performed since delivery from the works
.
4.6
To insert the press jaw
(D)
Remove battery!
Open the bolt (1).
Insert the appropriate press jaw for the job in hand (2).
Lock the bolt (3).
After changing the press jaw it is essential to ensure that, once engaged, the crimping jaw
matches the profile being moulded and the nominal width of the fitting being moulded. A visual
inspection must be carried out in order to determine that the press jaw is fully closed at the end
of the press cycle.
4.7
Operation
(E)
Use only system-compatible press fittings and press jaws designed for them. The nominal size
of the press jaw must be identical with the nominal size of the press fitting.
When inserting the pipe / press fitting system, there is a risk of crush injuries for the
fingers or other body parts near the press jaw!
Push the press fitting on to the pipe (1). Pull the press jaw apart and insert the pipe with the
press fitting at right angles.
There must be no foreign bodies between the press contour and the fitting. If you fail to
ensure this, the pressing process will not produce a perfect joint!
Press the ON button until the pressing process has been completed (2). The motor cut out
indicates the end of the moulding cycle.
Push the press jaw apart and take the machine off the joint (3).
Do not start the machine while the piston retracts or the emergency shutdown is pressed!
4.8
Charger and battery
(F)
Overview:
1
Battery pack
4
Warning display
2
Sliding seat
5
Capacity indicator button
3
Operation display
6
Capacity and signal indicator
Start of operation
Before plugging in, check to see that the rated mains voltage and mains fre-
quency, as specified on the rating label, match your power supply.
Devices such as this one, which generate direct current, may have an effect on basic residual-
current circuit breakers. Use type F or better, with a release current of max. 30 mA.
Before commissioning the charger, ensure that the air slots are free. Minimum
distance to other objects is 5 cm.
Self-test:
Insert mains supply plug.
The warning display (4) and the operating indicator (3) light up one after the other for approx. 1
second and the installed fan runs for approx. 5 seconds.