NOTE – to navigate use up/down to select setting and left/right to change setting
Mode/Fan Speed:
Mode:
Select your mode of operation (see steps on next page)
Fan Speed:
Sets the speed of the fan
Delay Time:
Amount of time the air curtain is to run after the door closes
Temp Set:
Amount of heat and time the air curtain is to run after the door closes
Start Time:
Programmable time of day air curtain becomes active
Stop Time:
Programmable time of day air curtain stops running
T-Stat Mode:
Set only heat or heat & fan
Set Time/Day:
Programmable clock
Locked:
Unit will run as programmed but settings cannot be changed
QUICK
START INSTRUCTIONS
For your Berner Air Curtain with Intelliswitch™
IMPORTANT NOTE!
If your air curtain unit is in “Locked” mode when you receive it:
Press and hold the left and right arrows simultaneously for 5 seconds to unlock.