Installation and connection
52
8LVA user's manual V1.0
5.5.4.2 Single-cable solution (hybrid)
•
300° swivel connector
•
Encoder and power conductor in one cable
•
Quick-release self-locking connector system
•
Robust industrial connectors with optimal EMC shielding
•
Robust metal housing
Note:
The following conditions must be met by the drives in order to operate a motor with a hybrid connector.
•
For ACOPOSmulti: The cable cover must be designed for operation with a hybrid cable (cable
cutout present, delivered 2015 or later)
•
For ACOPOSmulti with SafeMOTION: The configured operating system version (NC version)
must be set to V2.48.0 or later; the Safety Release must be V1.9 or later.
•
For all drives: The configured operating system version (NC version) must be set to V2.42.2
or later.
5.5.4.2.1 Single-cable solution (hybrid) - Pinout
Pin Signal
A
Motor connection U
B
Motor connection V
C
Motor connection W
D
---
7
Brake -
8
Brake +
PE Grounding
1
Up
2
Ground
3
Data
4
Data inverted
5
Clock input
7
8
A
B C
D
1
2
3
4
6
5
6
Clock input inverted
5.5.4.2.2 htec connector - Dimensions
The htec connector from Intercontec can be connected without tools.
htec connector
htec connector
Length (1)
Diameter (D)
W1
W2
Encoder connectors
77.8 mm
27.9 mm
25 mm
24 mm