Start-up / Operation • Recommended Monitoring Devices
Chapter 3
Start-up
/ Operat
ion
85
Mobile Panel User's Manual V 1.5
3. Recommended Monitoring Devices
B&R recommends using PNOZ e1.1p or PNOZ e2.1p safety relays from the Pilz company
(
) in order to achieve Safety Category 4 in accordance with EN 954-1. As a
monitoring device for the E-stop button, the PNOZ e1.1p can be used for safety circuits up to
Safety Category 4 according to EN 954-1. It is imperative to use the PNOZ e2.1p as a monitoring
device for the enable switch for safety circuits up to Category 4 (EN 954-1).
Caution!
Pressing several function or system keys at the same time may trigger unintended
actions.
Information:
•
Protective coverings on the device, housing screws, and damage to the
housing and cables should all be checked periodically.
•
For instructions on cleaning the Mobile Panel device, see "Cleaning", on
page 135.
Figure 43: Pilz PNOZ e1.1p (left) and Pilz PONZ e2.1p (right)
Warning!
If EN 954-1 Safety Categories 2, 3, and 4 are not necessary, safeguards can be
switched directly on the E-stop circuit for Categories B and 1. When doing so, be
aware of EN 954-1 and EN ISO 13849-2 guidelines as well as the max. permitted
current load on the E-stop button and the key switch! More information can be found
in the section 3.3 "Current Load of the Enable Switch and Entry Device Circuit" on
Page 92.
Summary of Contents for 4MP181.0843-03
Page 2: ...2 Mobile Panel User s Manual V 1 5...
Page 4: ...4 Mobile Panel User s Manual V 1 5...
Page 6: ...6 Mobile Panel User s Manual V 1 5...
Page 134: ...134 Accessories USB Memory Stick Mobile Panel User s Manual V 1 5...
Page 144: ...144 Maintenance Servicing Changing the Battery Mobile Panel User s Manual V 1 5...
Page 160: ...Model Number Index 160 Mobile Panel User s Manual V 1 5...