10.5
Connecting the machine to the electrical mains
Ensure that the data relating to the power line correspond both to those indicated on the identification
plate on the machine and the electric box and to those outlined in the Technical Data in this manual.
Before connecting, ensure that the electrical parts to work on are not powered. Insert the plug of the
power cable in the socket on the side of the machine and in the socket provided in the workplace.
10.6
Machine adjustment
The machine does not require any preliminary adjustment for operation.
11.
OPERATING AND USING THE MACHINE
11.1
Operation
To operate the machine, correctly installed and prepared for use, you need to heed the following
warnings:
Position the differential switch upstream of the machine in the closed position “
”.
The operator must wear individual protection devices planned for the work carried out. Then
you must stand in such a way to have perfect and comfortable visibility of all the signs and
commands.
11.2
Using the machine
To correctly use the machine, refer to paragraph 6.2.
12.
MAINTENANCE AND REPAIR
12.1
Maintenance
The machine does not require any particular maintenance operations, except for cleaning the tanks and
the machine. The machine works well only if the Tanks and its parts are clean.
Cleaning the tanks.
Switch off the machine by placing the main sectioning switch in position “
”, then section the
machine by separating the plug from the power socket.
Ensure the machine and the tanks are cold and wait for them to cool down.
Wear IDP, remove the tanks from the machine casing, empty and correctly dispose of the
galvanic solutions, then rinse with plenty of running water. For more stubborn residue, clean
with soft sponges and, if necessary, with plastic tools that won't scratch the tanks.
Correctly place the tanks in their compartment inside the machine casing.
ATTENTION:
Dispose of used galvanic liquids following the instructions in the reference SDS Safety
Data Sheet of the solutions used.
Electrical connection maintenance.
The electrical power cable must be periodically checked and it must be replaced if not in good working
condition.
Replacing the fuse:
The machine is protected with a 5 A 220Vca fuse. The fuse is hosted in a drawer in the mains socket in
the side of the machine casing.
Summary of Contents for GALVALINK 302B
Page 2: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 2 ...
Page 25: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 25 ANNEX 5 ELECTRICAL CIRCUIT DIAGRAM ...
Page 34: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 34 ...
Page 35: ...01 12 14 Manuale Uso GALVALINK_302B_v3_14 EN Completo 35 ...