Berkeley 6S Series Owner'S Manual Download Page 11

11

Please be sure to include pump model number,
horsepower, GPM rating and any other pertinent
information when ordering pump parts.

Repair Parts List

6S/E6S Series

Submersible Turbine Pumps

Key

Part

No.

Description

Qty.

Suction Bracket

1

2

Inner Strainer

1

3   

Coupling

1

4   

Spline Bushing

1

5   

Coupling Lock Screw

1

6   

M8 Allen Screw

1

7   

Pump Shaft

1

8   

Guide Sleeve

*

9   

Standard Guide Housing

2

10 

Suction Stage Plate

1

11 

Impeller

*

12 

Stage Casing

*

13 

Diffuser

*

14 

Standard Stage Plate

*

15 

IGH Stage Plate

*

16 

Intermediate Guide Housing (IGH)

*

17 

Discharge Stage Plate

1

18 

Spacer

1

19 

Upthrust Washer

1

20 

Top Guide Sleeve

1

21 

Shaft Lock Washer

1

22 

NRV Ring

1

23 

Check Valve

1

24 

Discharge Outlet

1

25 

Strap

4

26 

Strap Nut

4

27 

M12 Spring Washer

4

28 

M12 Hex Bolt

4

29 

Outer Strainer

1

30 

Cable Guard

1

31 

4mm Washer

6

32 

M4 Screw

6

* Quantity determined by number of stages. See Table VI, 

Page 9, for Intermediate Guide Housing locations.

Summary of Contents for 6S Series

Page 1: ...nt wear and reduce pump capacity and discharge pressure Never use the pump to develop or clean the well Permanent pump damage can result within the first few hours of operation If the well casing is s...

Page 2: ...Insert wires into connector until insulation butts up against connector Crimp connector to wires with a pair of crimping pliers Pull on cable to make sure the connection is solid and tight 2 SPECIFIC...

Page 3: ...the leak is in the splice 4 If leak is not in splice slowly pull cable out of water until reading changes to infinity Reading will change to infinity when leak comes out of water 5 Repair cable by spl...

Page 4: ...alified electricians should perform these tests When testing use all normal precautions for the voltages involved Electrical test of motor cable connections The cable and splices can be damaged as the...

Page 5: ...s L3 53 Amps L3 52 Amps L3 51 Amps Total 150 Amps Total 150 Amps Total 150 Amps B Divide each total by three to get average amps Example 150 3 50 Example 150 3 50 Example 150 3 50 C For each hookup fi...

Page 6: ...not be freed disconnect pump from motor disassemble liquid end see Page 7 and backwash sand from each part Checking Pump Performance Water containing abrasives can cause impeller wear and reduce impel...

Page 7: ...s 28 and 27 and remove the straps 4 Gently tap the Discharge Key No 24 and remove it 5 Gently tap the Guide Housing Key No 9 and remove it 6 Loosen the M8 Allen Screw in the top of the Shaft Key No 6...

Page 8: ...ntly tapping it with a rubber mallet 9 Slide an Impeller Key No 11 over the Shaft until it rests on the Guide Sleeve Key No 8 10 Slide the first Stage Casing Key No 12 over the Shaft and seat it on th...

Page 9: ...ns Number of Number of Stages Guide Housings Required 0 12 0 13 24 1 at Midpoint of Shaft 25 37 2 at 1 3 and 2 3 Length of Shaft Space Intermediate Guide Housings evenly 9 PREVENTIVE MAINTENANCE To av...

Page 10: ...1 12 13 31 32 8 16 15 11 14 11 17 18 19 20 21 6 9 22 25 26 2 1 32 31 32 24 23 12 5 8 9 27 28 32 29 13 12 13 25 30 30 121 20 48 5 43 5 9 25 4 25 121 20 121 30 121 20 121 30 121 20 Assembly Fixture 3367...

Page 11: ...Standard Guide Housing 2 10 Suction Stage Plate 1 11 Impeller 12 Stage Casing 13 Diffuser 14 Standard Stage Plate 15 IGH Stage Plate 16 Intermediate Guide Housing IGH 17 Discharge Stage Plate 1 18 Sp...

Page 12: ...agnetic controller coil 4 Check starter and coil Pump does not shut off 1 Cable leads improperly connected 1 Check wiring diagram on box cover for correct connections Motor runs but delivers 1 Horizon...