END USER

END USER INSTRUCTIONS

Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information.

22  START-UP

The heater commissioning must be performed by Techni-

cal Assistance Centre personnel.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Centre. Before doing so, perform the 

following checks and operations.

-  Check that the supply cocks in the domestic water 

circuit are all open

-  Check that the system main switch and the control 

main switch are active "ON".

For further information concerning the solar regula-

tor, refer to the dedicated manual supplied with the 

product.

End user

23  TEMPORARY SHUTDOWN

To reduce to the environmental impact and save energy, 

in case of brief absences, week-ends, short trips, etc., and 

with external temperatures above 0°C, set the heater tem-

perature control, where available, to the minimum value.

If the temperature to which the heater is exposed can 

fall below 0°C (frost hazard), perform the operations 

described in paragraph "Preparing for extended pe-

riods of disuse".

24  PREPARING FOR EXTENDED 

PERIODS OF DISUSE

If the storage cylinder is not going to be used for an ex-

tended  period  of  time,  ask  the  manufacturer’s  Technical 

Assistance Centre to make the system safe.

25  EXTERNAL MAINTENANCE

Clean the outside of the storage cylinder with a soft cloth 

damped in soapy water.

Use a dry cloth to clean the insulation and the solar regula-

tor display to remove any dust.

Do not use abrasive products, petrol or triethylene.

Summary of Contents for IDRA DS 200 FI

Page 1: ...Installation and Operation Manual Solar Solar storage cylinder IDRA DS FI Installation and Operation Manual EN...

Page 2: ...following symbols are used in this manual b CAUTION Identifies actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do This manual Code Rev comprises page...

Page 3: ...p the product purchase documents to be presented to the B authorised Technical Assis tance Centre to request a service call under warranty b Size the solar expansion tank so as to ensure com plete abs...

Page 4: ...chieved thanks to Safety valve with trigger pressure set at 6 bar Solar Regulator for circulator management adjust ment It manages 9 system diagrams that can be se lected Refer to the specific manual...

Page 5: ...urn valve 2 Delivery Valve solar plant delivery with built in non return valve 3 Outlet temperature gauge 4 Return temperature gauge 5 Insulation 6 Solar controller 7 Display 8 Multidirectional joysti...

Page 6: ...TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 kW 400 572 774 774 l h 70 C T 20 C 10 3 17 20 7 20 7 kW 2...

Page 7: ...t 70 C 374 438 659 863 l 60 C 284 375 531 675 l 50 C 205 310 390 485 l DESCRIPTION SOLAR STATION TECHNICAL DATA Safety valve calibration pressure 6 bar Maximum operating temperature 110 C Power supply...

Page 8: ...recommended for a correct maintenance and access to the device b When installing the boiler allow sufficient space around it to access all safety and control devices and to permit easy maintenance 11...

Page 9: ...50 1 33 450 1 33 520 1 33 520 mm DF Flange internal diameter 130 130 130 130 mm A 1120 1420 1270 1570 mm B 171 171 208 207 mm C 403 393 427 443 mm D M8 threaded inserts for grounding point accessory h...

Page 10: ...mnipolar magneto thermal circuit breaker and a disconnecting switch compliant with the pre vailing standards of the installation country respect the polarity of the L1 Phase N Neutral connections use...

Page 11: ...together with mains power cables and or AC cables Absolutely avoid routing cables close to strong mag netic fields Avoid any cable jointing as much as possible solder and duly insulate any indispensa...

Page 12: ...VR counter clockwise Close taps A and B b During system flushing pay attention to water com ing out of the taps as vapour could be released with risk of burns or scalds Use suitable personal protec ti...

Page 13: ...een eliminated Close the manual bleed valve and any vent valves opened previously Turn handle on valve VR counter clockwise Temporarily raise the pressure in the system to 4 bar Start up the system fo...

Page 14: ...any wiring and electric devices below to protect them against any leakage of heat transfer fluid Close valves VR and VM by turning handle clock wise by 90 Open taps A and B and drain the solar circui...

Page 15: ...he product End user 23 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the hea...

Page 16: ...23 A 23900 Lecco LC www berettaboilers com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore...

Reviews: