Thank  you  for  choosing  this  radio  frequency  (RF)  radiostat. 
This  central  heating  control  device  is  easy  to  fit,  and  with 
correct use,  will  deliver  improved  comfort  levels  in  your  home 
whilst saving you money. 
This  thermostat  is  designed  to  be  used  only  with  heating 
controls  system  with  a  maximum  switching  load  of  2A  at 
30VDC or 0,25A at 230VAC. 
If  installing  for  someone  else,  please  ensure  that  the 
instructions are handed to the householder. 
W

ARNING

: Please read this manual prior to installation or use. 

S

HOCK 

H

AZARD

:  This  unit  must  be  installed  by  a  competent 

person,  in  accordance  with  BS  7671  (the  IEE  Wiring 
Regulations), or other relevant national regulations and codes 
of  good  practice.  Always  isolate  the  AC  Mains  supply  before 
installing this unit. 
 

FIRST INSTALLATION WARNING

. 

The  product  arrives  ready  to  use,  the  only  action  required  by 
the  installer  is  the  wiring  connections  of  the  receiver  to  the 
boiler.  Coupling  between  receiver  and  transmitter  is  already 
pre-configured at the factory. 
 
I

MPORTANT

:  these  instructions  should  be  read  in  conjunction 

with  the  appliance installation instructions.  It is  recommended 
that this device is installed by a qualified electrician. 
 
 

E

NCODER KNOB

 

Encoder 

movements: 

clockwise 

and 

anticlockwise rotation. 
Encoder  clockwise  and  anticlockwise 
rotation:  
increase  or  decrease  the  room 
comfort  temperature.  The  selected  value 

start  to  blink  5  times;  after  this  blinking  period  the  comfort 
temperature value is automatically entered. 
Encoder  rotation  one  step:  check  the  selected  comfort 
temperature. The value will blink for few times and later it will 
be back to the room temperature value display. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

D

ISPLAY

 

E

NCODER

 

S

ENSOR

 

O

PENING

 

Summary of Contents for Alpha DGT

Page 1: ...WIRELESS manual issue 12 2012 rev 00 WIRELESS RF ROOM THERMOSTAT Installation and user instruction page 2 EN TERMOSTATO AMBIENTE SENZA FILI Manuale di installazione e uso pag 7 IT...

Page 2: ...e AC Mains supply before installing this unit FIRST INSTALLATION WARNING The product arrives ready to use the only action required by the installer is the wiring connections of the receiver to the boi...

Page 3: ...eceiver led colors and functionality LED FUNCTIONS REASON Led green ON constantly Relay closed heating request ON Signal received from the transmitter or end user manual button pressing Led red ON con...

Page 4: ...ing the screws and wall plugs or using the adhesive magnetic strips on the external boiler casing including to fix both fixing tools are provided The location should be chosen in order to see the rece...

Page 5: ...temperature value Follow the correct positioning of the batteries according to the internal transmitter battery box indications Every time the batteries are removed the set temperatures and the trans...

Page 6: ...o not alternate the values with the hands heat ENCODING The coupling between the receiver and the transmitter is factory done however if necessary it is possible to make again the coupling Press the b...

Page 7: ...ini di installazioni elettriche Staccare sempre l alimentazione elettrica prima di procedere all installazione ATTENZIONE PER L INSTALLATORE Il prodotto arriva gi pre impostato da fabbrica il minimo r...

Page 8: ...do si disattiva il riscaldamento contatto del rel aperto 2 Premendo per 5 secondi inizia la procedura di codifica della radio frequenza Premendo di nuovo si conferma o si esce Led del ricevitore color...

Page 9: ...icevitore siano compatibili vedi paragrafo specifiche tecniche La non compatibilit comporta un mal funzionamento e pericolosit dell installazione I terminali blu e marrone sono per alimentazione del r...

Page 10: ...izza onde radio per comunicare con il ricevitore tenere presente che oggetti metallici possono indebolire o deviare il segnale attenzione a pareti in cemento armato molto spesse armadi elettrodomestic...

Page 11: ...troppo elevata o disturbi interni all edificio come muri in cemento armato o altri disturbi elettronici Una volta ripristinata la comunicazione il termostato senza fili ritorna automaticamente nella...

Page 12: ...ulsante posto sul lato inferiore Individuare sul circuito stampato interno il pulsante segnato come KEY1 Premere per 5 secondi il pulsante fino a quando a display non viene mostrato un valore questo v...

Reviews: