1 | GENERAL INFORMATION
7
Outdoor unit data
Model
18000-2
Nominal capacity
kW
5
Nominal power input
kW
1,45
Rated frequency
Hz
64
Maximum frequency
Hz
100
Minimum frequency
Hz
15
Nominal current consumption
A
6,50
Max. current input
A
11,50
Minimum current consumption
A
1,60
Nominal capacity
kW
5,20
Nominal power input
kW
1,40
Rated frequency
Hz
78
Maximum frequency
Hz
118
Minimum frequency
Hz
20
Nominal current consumption
A
6,30
Max. current input
A
12,50
Minimum current consumption
A
2,50
Electrical characteristics
Power supply
V/Ph/Hz
220-240/1/50
Compressor
Compressor
Tipo
Rotativo Doppio
Oil
Tipo
RM-LP56EG
Oil charge
l
0,48
Refrigerant
Tipo
R32
Refrigerant charge
kg
1,40
Fan
Fan
Tipo
Assiale - DC
Quantity
n.
1
Maximum air flow
m³/h
2400
Minimum speed
Rpm
500
Maximum speed
Rpm
900
Maximum power input
kW
0,04
Cooling sound levels
Sound power level
dB(A)
62
Sound pressure level
dB(A)
55
Heating sound levels
Sound power level
dB(A)
63
Sound pressure level
dB(A)
56
(1) Outdoor air: 35 °C D.B., Indoor air: 27 °C D.B. / 19 ° W.B.