25
Par.
Ref.
Desc.
Factory
set value
Type
Operation
11
Influence of
temperature
sensor
10
(0÷20)
Type
rEc
Use the
button to decrease and the
button
to increase the influence of room sensor on the
calculation of the boiler flow temperature. 10 is
the standard, higher values is good for pour
insulation houses. The value is automatically
memorized when moving to the next parameter.
13
Calibration of
the room
sensor
Actual
Type
rEc
and crt
Use the
button to decrease and the
button
to increase the reference room temperature. Use
this parameter in case of not proper installation of
the device. The value is automatically memorized
when moving to the next parameter.
14
Programmer
reset
0
Type
rEc
and crt
Use the
button to move to value 1 and reset
the device to a factory set values. Press the
button to confirm the reset.
16
Software
release
Actual
Type
rEc
and crt
This parameter just shows the software reference
number on the device