12
Installation
6005737_0 – 31.03.2021
3.5.4
Hanging the device in place
The device is designed to be hung on walls. The chimney can
be adapted to the ceiling height by pulling it out.
When mounting on a solid wall:
☞
Make sure that the wall has sufficient load bearing
capacity.
☞
Use the fastening materials provided.
With different installation situations:
☞
Enquire about alternative fastening systems (e.g. consult
with your architect).
☞
Only use fastening hardware suitable for the type of wall.
x
478
30
270
508
30
290
=
=
600
Safety distance (x):
y
Recommendation 700 mm.
y
With electric hobs, at least 600 mm.
y
With gas hobs, at least 650 mm.
Observe the specifications for the cooking appliances
(e.g. installation above a solid fuel stove).
☞
Determine the hanging position.
☞
Ensure that the chimney mount is correctly positioned:
y
The chimney cannot be mounted if it falls below the
required measurement (30 mm).
y
Any irregularities (e. g. in the ceiling) can be
compensated with slotted holes.
☞
Make sure that the safety distance is complied with.
D
WARNING!
Risk of death due to explosions or electric shock!
Drilling through gas, water or electrical lines can lead to
hazardous situations.
☞
Ensure that there are no lines in the wall at the fastening
points.
Ø 8
☞
Determine the locations of the fastening points and mark
them.
☞
Drill the holes in the wall.
☞
Insert the wall plugs into the holes.
☞
Screw the chimney fastening bracket on.