Appendix 4
Page 34 Issue 2
Lubricant Quantities (Litres)
K0332
K0432
K0532
K0632
K0732
K0832
K0931
K1031
K1231
1
0.5
0.7
1.1
1.5
2.7
4.4
9.3
15
23
2
0.7
0.9
1.5
1.8
3.6
3.7
8.3
15
27
3
0.8
1.1
1.7
2.8
4.0
7.6
18
28
33
4
1.0
1.3
1.9
2.7
4.5
7.5
17
30
39
5
1.2
1.7
2.5
3.6
5.7
9.6
21
34
50
6
0.9
1.2
2.0
2.6
4.5
7.6
16
25
35
Primary
Secondary
Primary
Secondary
Primary
Secondary
Primary
Secondary
Primary
Secondary
M0122
K0332
M0122
K0432
M0322
K0532
M0322
K0632
M0322
K0732
1
0.5
0.5
0.5
0.7
0.8
1.1
0.8
1.5
0.8
2.7
2
0.5
0.7
0.5
0.9
0.8
1.5
0.8
1.8
0.8
2.7
3
0.5
0.8
0.5
1.1
0.8
1.7
0.8
2.8
0.8
2.7
4
0.5
1.0
0.5
1.3
0.8
1.9
0.8
2.7
0.8
2.7
5
0.7
1.2
0.7
1.7
1.1
2.5
1.1
3.6
1.1
5.7
6
1.0
0.9
1.0
1.2
1.4
2.0
1.4
2.6
1.4
4.5
Primary
Secondary
Primary
Secondary
Primary
Secondary
Primary
Secondary
M0522
K0832
M0522
K0931
M0722
K1031
M0722
K1231
1
1.5
4.4
1.5
9.3
2.6
15
2.6
23
2
1.5
3.7
1.5
8.3
2.6
15
2.6
27
3
1.5
7.6
1.5
18
2.6
28
2.6
33
4
1.5
7.5
1.5
17
2.6
30
2.6
39
5
2.0
9.6
2.0
21
3.2
34
3.2
50
6
2.6
7.6
2.6
16
4.7
25
4.7
35
SERIES K LUBRICATION
M
O
UN
T
ING
PO
SI
T
IO
N
K0352
Unit Size
K03,K04,K05,K06,& K07 Units & Prim ary Units used for Quintuple Reduction,
are supplied factory filled w ith EP mineral oil (Grade
6E) appropriate to the intended mounting position. If the unit is supplied w ithout lubricant the unit must be filled w ith the the correct
lubricant and quantity as listed below .
K08,K09,K10,& K12 Units,
require filling w ith EP mineral oil (Grade 6E)
Lubricant quantities are approximate fill until oil escapes from the level plug hole, fit ventilator plug (w hen supplied) in the appropriate
position for the required mounting position. If the unit is supplied w ithout lubricant the unit must be filled w ith the correct lubricant and
quantity.
Unit Size
TRIPLE REDUCTION
K0752
QUINTUPLE REDUCTION
K1251
MO
U
N
T
IN
G
PO
SI
T
IO
N
K0452
K0552
K0652
QUINTUPLE REDUCTION..CONT
MO
U
N
T
IN
G
PO
SI
T
IO
N
K0852
K0951
K1051
Unit Size
Summary of Contents for C Series
Page 15: ...Appendix 1 Page 13 Issue 2 ...
Page 20: ...Appendix 2A Page 18 Issue 2 Series C K F Shaft Mount Units Alternative Shaft Fixing Methods ...
Page 24: ...Appendix 2C Page 22 Issue 2 Shrink Disc Installation Maintenance ...
Page 25: ...Appendix 2D Page 23 Issue 2 Series C Torque Bracket Dimensions ...
Page 27: ...Appendix 2D Page 25 Issue 2 Series K Torque Bracket Dimensions ...
Page 33: ...Appendix 4 Page 31 Issue 2 ...
Page 35: ...Appendix 4 Page 33 Issue 2 ...
Page 37: ...Appendix 4 Page 35 Issue 2 ...
Page 39: ...Appendix 4 Page 37 Issue 2 ...