Appendix 2A
Page 15 Issue 2
Series C, K & F Standard Bore Assembly.
UNIT
Bore
d
da
l
l1
l2
l3
l4
l5
m
R
T
u
u1
22.000/
21.946
28.000/
27.948
0.6
0.4R
0.6
0.4R
1.2R
0.8R
71.0
70.8
90.0
89.8
53
46
M20 x 2.5
42 deep
M24 x 3.0
50 deep
225.5
225.0
238.5
238.0
3
10
120
150
40
45
79.6
99.6
260
327
C10
Reduced
Std
79.990/
79.971
99.988/
99.966
20.000/
19.948
25.000/
24.948
0.6
0.4R
0.6
0.4R
1.2R
1.2R
62.5
62.3
81.0
80.8
58
58
M20 x 2.5
42 deep
M24 x 3.0
50 deep
177.5
177.0
221.5
221.0
3
3
105
135
35
45
69.6
76.6
227
227
C09
Reduced
Std
69.990/
69.971
89.988/
89.966
18.000/
17.957
20.000/
19.948
0.4
0.25R
0.6
0.4R
1.2R
1.2R
53.0
52.8
62.5
62.3
37
37
M20 x 2.5
42 deep
M20 x 2.5
42 deep
148.5
148.0
177.5
177.0
3
3
91
105
31
35
59.6
183
69.990/
69.971
69.6
183
C08
Reduced
Std
59.990/
59.971
44.5
44.3
14.000/
13.957
0.4
0.25R
M20 x 2.5
42 deep
1.2R
53.0
52.8
18.000/
17.957
0.4
0.25R
35
38
M16 x 2
38 deep
1.2R
130.5
130.0
148.5
148.0
3
3
75
90
25
30
49.6
59.6
153
153
C07
Reduced
Std
49.991/
49.975
59.990/
59.971
0.8R
39.5
39.3
14.000/
13.957
0.4
0.25R
101.5
101.0
3
31
M16 x 2
36 deep
44.6
125
68
23
0.8R
35.0
34.8
12.000/
11.957
0.4
0.25R
100.5
100.0
3
31
M16 x 2
36 deep
39.6
125
60
20
C06
Reduced
Std
39.991/
39.975
44.991/
44.975
0.8R
30.0
29.8
10.000/
9.964
0.16
0.25R
77.3
77.0
3
23
M12 x 1.75
28 deep
34.6
104
53
18
0.8R
26.0
25.8
8.000/
7.964
0.16
0.25R
79.3
79.0
3
23
M10 x 1.5
22 deep
29.6
104
45
15
C05
Reduced
Std
29.993/
29.980
34.991/
34.975
0.8R
26.0
25.8
8.000/
7.964
0.16
0.25R
0.16
0.25R
29.993/
29.980
29.6
99
45
15
79.3
79.0
3
26
M10 x 1.5
22 deep
M10 x 1.5
22 deep
0.8R
21.0
20.8
8.000/
7.964
Std
C04
24.993/
24.980
24.6
16.5
16.4
6.000/
5.970
0.16
0.25R
Reduced
99
38
13
79.3
79.0
3
23
3
22
M6 x 1.0 16
deep
0.8R
82
30
10
61.3
61.0
C03
Std
19.993/
19.980
19.6
F03 & K03
-
29.993/
29.980
29.6
82
45
15
70.3
70.0
26.0
25.8
8.000/
7.964
0.16
0.25R
3
23
M10 x 1.5
22 deep
0.8R
F04 & K04
-
34.991/
34.975
34.6
109
60
20
90.5
90.0
3
23
M12 x 1.75
28 deep
0.8R
30.0
29.8
10.000/
9.964
0.16
0.25R
F05 & K05
-
39.991/
39.975
39.6
112
60
20
35.0
34.8
12.000/
11.957
0.4
0.25R
92.5
92.0
3
30
M16 x 2
36 deep
126
75
25
0.8R
F06 & K06
-
39.991/
39.975
39.6
100.5
100.0
3
30
M16 x 2
36 deep
0.8R
35.0
34.8
12.000/
11.957
0.4
0.25R
F07 & K07
-
44.991/
44.975
49.6
153
75
25
101.5
101.0
44.5
44.3
14.000/
13.957
0.4
0.25R
3
30
M16 x 2
36 deep
0.8R
F08 & K08
-
59.990/
59.971
59.6
173
90
30
148.5
148.0
3
37
M20 x 2.5
42 deep
0.8R
53.0
52.8
18.000/
17.957
0.4
0.25R
F09 & K09
-
69.990/
69.971
69.6
232
105
35
161.5
161.0
3
38
M20 x 2.5
42 deep
0.8R
62.5
62.3
20.000/
19.948
0.6
0.4R
F10 &K10
-
79.990/
79.971
79.6
275
120
40
188.5
188.0
5
37
M20 x 2.5
42 deep
0.8R
71.0
70.8
22.000/
21.946
0.6
0.4R
K12
-
99.988/
99.966
99.6
327
150
45
238.5
238.0
10
46
M24 x 3.0
50 deep
0.8R
90.0
89.8
28.000/
27.948
0.6
0.4R
F02
-
24.9931/
24.980
24.6
82
40
13
70.3
70.0
21.0
20.8
8.000 /
7.964
0.16
0.25R
3
23
M10 x 1.5
22 deep
0.8R
See next page for shaft assembly instructions
Summary of Contents for C Series
Page 15: ...Appendix 1 Page 13 Issue 2 ...
Page 20: ...Appendix 2A Page 18 Issue 2 Series C K F Shaft Mount Units Alternative Shaft Fixing Methods ...
Page 24: ...Appendix 2C Page 22 Issue 2 Shrink Disc Installation Maintenance ...
Page 25: ...Appendix 2D Page 23 Issue 2 Series C Torque Bracket Dimensions ...
Page 27: ...Appendix 2D Page 25 Issue 2 Series K Torque Bracket Dimensions ...
Page 33: ...Appendix 4 Page 31 Issue 2 ...
Page 35: ...Appendix 4 Page 33 Issue 2 ...
Page 37: ...Appendix 4 Page 35 Issue 2 ...
Page 39: ...Appendix 4 Page 37 Issue 2 ...