TECHNICAL DATA
172 215 44 07-01
Capacity chart according to
EN 676
1
) Calorific value:
Natural gas 10 kWh/Nm
3
LPG 26 kWh/Nm
3
2
) Depending on gas quality and
available pressure
Out range
The above dimensions are max. measurements. Depending on the compo
-
nents used, the measurements may vary.
Length of
burner tube
Flange A
Measure A
Standard
145
121,5
Long design
245
221,5
Type
Capacity
Nm
3
/h at min.
output of burner
1
)
Nm
3
/h at max
output of burner
1
)
Rated inlet pressures
mbar
STG 146
Natural gas
41-133
LPG
47-144
Natural gas
4,1
LPG
1,8
Natural gas
13,3
LPG
5,5
Natural gas
20
LPG
30
Connection
2
)
Motor
Ignition transformer
Natural gas, LPG
½"
220/240V,2800r/m,
50Hz, 70-90 W, 0,65A
Electronic
230/11000V, Ampl.
Type designation STG 146
Burner head 2
Dimensions
LPG
Natural gas
A
ø 89
202
61
192
139
290
244
10
145,0
23,5
109,5