9
Bentone
Max operating current, see data plate.
Burner correspond to IP20
Type
BG 450
Motor supply
450W 230V 3,3A 50Hz
The recommended main fuse
motor
C10A
Main supply
230V 3,3A 50Hz
Sound
89 dBA ± 0,5 dBA
2.2.4 Working field
BG 450
120-550 kW
-1
0
1
2
3
4
5
6
7
8
9
100
150
200
250
300
350
400
450
500
550
600
Mbar
kW
2.2.5 Electric Specification
!
Do not exceed working
field
Measurements according to EN 3746: 2010
Alt.1 The sound level of the burner can be reduced by equipping the burner
with silencer. Installation must be done so it does not prevent air supply
to the burner.
Alt.2 The burner’s noise level can be reduced by connecting the burner’s air
intake to the air duct that opens into an appropriate location. Installation
must be done so it does not prevent air supply to the burner.
172 525 23
2020-10-29 /3