9
Bentone BFG1
Measurements according to EN 3746: 2010
Alt.1 The sound level of the burner can be reduced by equipping the burner
with silencer. Installation must be done so it does not prevent air supply
to the burner.
Alt.2 The burner’s noise level can be reduced by connecting the burner’s air
intake to the air duct that opens into an appropriate location. Installation
must be done so it does not prevent air supply to the burner.
2.3.1 Gas categories, approved gases
Only dry gas is permitted for use
Gerätekategorien
Appliance categories
Versorgungsdrücke
Supply pressure
Bestimmungsländer
Countries of destination
II
2R/3R
20 mBar
AT, BE, BG, CH, CZ, CY, DE,
DK, EE, ES, FI, FR, GB, GR, HR,
HU, IE, IS, IT, LT, LU, LV, MK,
MT, NL, NO, PL, PT, RO, RS,
SE, SI, SK, TR
II
2H38/P
20 mBar
AT, CH, CY, DK, FI, LT, RO, SE,
SK
II
2H3P
20 mBar
GB, IE
II
2L38/P
20 mBar
NL, RO
II
2E38/P
20 mBar
PL
II
2E(R)B
20 mBar
BE
I
3P
20 mBar
BE
Burner correspond to IP20
2.3.2 Electric Specification
EN 60335-2-102
Type
BFG 1
Motor
110W, 0,9A, 230V, 50Hz,
2700Rpm
The recommended main fuse
motor
6,3A
Control power
1~230V 1,0A
Sound
79 dBA ± 0,5 dBA