background image

171 505 41  07-01

   

Gph

22

23

24

25

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

1,00

5,53

66

56

5,65

67

58

5,77

68

59

5,89

70

60

1,10

6,07

72

62

6,21

74

63

6,34

75

65

6,47

77

66

1,20

6,62

78

67

6,77

80

69

6,92

82

71

7,06

84

72

1,25

6,90

82

70

7,05

84

72

7,21

85

73

7,35

87

75

1,35

7,45

88

76

7,62

90

78

7,78

92

79

7,94

94

81

1,50

8,27

98

84

8,46

100

86

8,64

102

88

8,82

105

90

1,65

9,11

108

93

9,31

110

95

9,51

113

97

9,71

115

99

1,75

9,66

115

98

9,88

117

101

10,09

120

103

10,30

122

105

2,00

11,04

131

113

11,29

134

115

11,53

137

118

11,77

140

120

2,25

12,43

147

127

12,70

151

129

12,98

154

132

13,25

157

135

2,50

13,81

164

141

14,12

167

144

14,42

171

147

14,72

175

150

2,75

15,19

180

155

15,53

184

158

15,86

188

162

16,19

192

165

3,00

16,18

192

165

16,93

201

173

17,30

205

176

17,65

209

180

3,50

19,33

229

197

19,77

234

202

20,19

239

206

20,61

244

210

4,00

22,10

262

225

22,59

268

230

23,08

274

235

23,56

279

240

4,50

24,85

295

253

25,41

301

259

25,96

308

265

26,49

314

270

5,00

27,61

327

282

28,24

335

288

28,84

342

294

29,44

349

300

5,50

30,38

360

310

31,06

368

317

31,73

376

324

32,38

384

330

6,00

33,14

393

338

33,89

402

346

34,62

411

353

35,33

419

360

6,50

35,90

426

366

36,70

435

374

37,49

445

382

38,26

454

390

7,00

38,56

457

393

39,53

469

403

40,38

479

412

41,21

489

420

7,50

41,42

491

422

42,35

504

434

43,26

513

441

44,16

524

450

8,00

44,19

524

451

45,18

536

461

46,15

547

471

47,10

559

480

8,50

46,95

557

479

48,00

569

489

49,03

581

500

50,05

594

510

9,00

49,71

589

507

50,83

603

518

51,92

616

529

52,99

628

540

9,50

52,47

622

535

53,65

636

547

54,80

650

559

55,93

663

570

10,00

55,23

655

563

56,47

670

576

57,69

684

588

58,88

698

600

11,00

60,76

721

620

62,12

737

633

63,46

753

647

64,77

768

660

12,00

66,28

786

676

67,77

804

691

69,23

821

706

70,66

838

721

14,00

77,33

917

789

79,09

938

806

80,77

958

824

82,43

978

841

16,00

88,37 1048

901

90,36 1072

921

92,30 1095

941

94,20 1117

961

NOZZLE TABLE

2(2)

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

Summary of Contents for B 45 A2.2H

Page 1: ...Providing sustainable energy solutions worldwide 178 014 56 2014 11 11 Installation and maintenance instruction B 45 A2 2H...

Page 2: ......

Page 3: ...e 2 15 Solenoid valves 16 Nozzle assembly adjustment 17 Connecting pipe pump adjustment device 18 Adjustment device Nozzle assembly adjustment 19 Fuse 20 Indicating lamp Stage 2 21 Switch I II 22 Indi...

Page 4: ...and the spray pattern change with the pump pressure Output range and nozzles recommended The net calorific value of 11 86 kWh kg for light oil has been used Length of burner tube Flange Measure B B45A...

Page 5: ...TECHNICAL DATA 171 225 34 09 01 Dimensions of flange 14 134 200 224 260...

Page 6: ...optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminated or...

Page 7: ...stage Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity...

Page 8: ...and cut off the oil supply Service of burner head alt A Service of burner head alt B Note For maintenance of the brake plate nozzles electrodes etc when using a long design of the burner tube you have...

Page 9: ...l burner control LMO24 255 Wiring diagram ELECTRIC EQUIPMENT 1 3 1N 50 60 Hz 230 V If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance...

Page 10: ...es and the solenoid valve 1 opens 2 2 Solenoid valve 1 opens Oil mist is formed and ignited The photocell indicates a flame 3 The safety time expires a If no flame is established before this time limi...

Page 11: ...blem by pressing and holding the reset button for 3 seconds The number of flashes below is repeated with a pause in between 2 flashes No flame signal when safety time expires 4 flashes False light dur...

Page 12: ...length in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle ou...

Page 13: ...ic it is assured by a bleed flat on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump...

Page 14: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Page 15: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Page 16: ...23 34 277 238 6 00 22 34 265 228 23 42 278 239 24 47 290 250 24 46 302 260 6 50 24 20 287 247 25 37 301 259 26 51 314 270 27 58 327 281 7 00 26 06 309 266 27 33 324 279 28 55 339 291 29 70 352 303 7 5...

Page 17: ...70 317 272 6 00 26 43 313 270 27 49 326 280 28 27 335 288 29 13 345 297 6 50 28 63 340 292 29 63 351 302 30 62 363 312 31 55 374 322 7 00 30 84 366 314 31 91 378 325 32 98 391 336 33 98 403 374 7 50 3...

Page 18: ...9 256 220 4 50 22 47 266 229 23 09 274 235 23 69 281 242 24 28 288 248 5 00 24 97 296 255 25 65 304 262 26 33 312 268 26 98 320 275 5 50 27 47 326 280 28 22 335 288 28 96 343 295 29 68 352 303 6 00 29...

Page 19: ...3 56 279 240 4 50 24 85 295 253 25 41 301 259 25 96 308 265 26 49 314 270 5 00 27 61 327 282 28 24 335 288 28 84 342 294 29 44 349 300 5 50 30 38 360 310 31 06 368 317 31 73 376 324 32 38 384 330 6 00...

Page 20: ...magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell...

Page 21: ...nt conformes aux normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivan...

Page 22: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Page 23: ......

Page 24: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...