BGSM-100/120
47
G
G
G
G
G
Call All Numbers:
Select this option
to call all telephone numbers programmed for an individual event and play the
voice message assigned to it. If this option is not selected
, the dialer will end the voice calls as soon as one of them
has been completed successfully.
Call Confirmation:
Select this option if you want the dialer to wait for confirmation from the remote user that the voice
message has been received, otherwise the dialer will attempt to deliver the voice message again: the remote user can
send confirmation by pressing the
button on his/her telephone (only applies to touch-tone keypads).
,
,
,
,
,
CAUTION - By pressing the
button on your own telephone when listening to a voice message, both
the current telephone call and any others in progress may be blocked.
Periodic voice
This section is used to program periodic voice message options.
Date of first send:
Select the date on which the first periodic voice message is to be sent.
Time of first send:
Select the time at which the first periodic voice message is to be sent.
Interval:
Enter the interval (HH-DD) at which subsequent periodic voice messages are to be sent. The interval consists
of the following values:
– (HH) next message time - Select the hour value for the next periodic voice message. The interval for these values may
be set between 0 and 23.
– (DD) next message day - Select the day value for the next periodic voice message. The interval for these values may
be set between 0 and 365.
Update time:
Select this icon to get local date and time from the PC.
,
,
,
,
,
If the Communicator is not receiving power from an external supply connected to terminal [+V], when the
power supply is restored it will have to be reprogrammed, otherwise the periodic voice message schedule
may NOT be applied correctly.
Local Service Mode
By selecting the
Local service mode
button, remote programming of voice messages can be enbled. When this mode is
enabled, the green LEDs L1 and L2 flash (see
Status Leds->table 2
). The LEDs only stop flashing when the recording or
replaying procedure is complete, or after 60 seconds have elapsed without any of the buttons being pressed.
SMS dialer (BGSM-120 series only)
This page is used to program all operating and SMS message options when using the Communicator as an SMS dialer. It
is also possible to set the first 3 input lines to Service mode.
Event type:
The ‘Event type’ column has 11 separate lines listing the events for which two SMS messages are sent,
if programmed: one for activation and one for resetting (the "Periodic SMS" event only sends an activation SMS).
,
,
,
,
,
To select SMS messages for the 3 programmable input lines, set the corresponding terminal as an input
(see I/O->Type).
Telephone numbers:
Click the ‘12345678’ columns in accordance with the desired input. A tick
indicates that the
SMS message will be sent to a particular telephone number when the corresponding event occurs.
,
,
,
,
,
The telephone numbers are the first 8 entries on the “Phonebook” page.
SMS String:
In the ‘
SMS String
’ column, click the box corresponding to the message to be programmed and enter the
message you wish to send when the relevant event occurs (maximum 100 characters).
Periodic SMS
This section is used to program periodic SMS message options.
Date of First Send:
Select the date on which the first periodic SMS message is to be sent.
Time of First Send:
Select the time at which the first periodic SMS message is to be sent.
Interval:
Enter the interval (HH-DD) at which subsequent periodic SMS messages are to be sent. The interval consists
of the following values: