79
6
Function
Code
Name
Setting Range
Default
Change
Group A1: Virtual DI/DO (continued)
A1-14
VDO4 function selection
0: Short with physical DIx internally
1 to 41: See physical DO selection in group F5
0
✩
A1-15
VDO5 function selection
0: Short with physical DIx internally
1 to 41: See physical DO selection in group F5
0
✩
A1-16
VDO1 output delay
0.0s to 3600.0s
0.0s
✩
A1-17
VDO2 output delay
0.0s to 3600.0s
0.0s
✩
A1-18
VDO3 output delay
0.0s to 3600.0s
0.0s
✩
A1-19
VDO4 output delay
0.0s to 3600.0s
0.0s
✩
A1-20
VDO5 output delay
0.0s to 3600.0s
0.0s
✩
A1-21
VDO active mode
selection
0: Positive logic active
1: Negative logic active
Units position: VDO1
Tens position: VDO2
Hundreds position: VDO3
Thousands position: VDO4
Ten thousands position: VDO5
00000
✩
Group A2: Motor 2 Parameters
A2-00
Motor type selection
0: Common asynchronous motor
1: Inverter duty motor
0
★
A2-01
Rated motor power
0.1 to 1000.0 kW
Model
dependent
★
A2-02
Rated motor voltage
1 to 2000 V
Model
dependent
★
A2-03
Rated motor current
0.01 to 655.35 A (AC drive power ≤ 55 kW)
0.1 to 6553.5 A (AC drive power > 55 kW)
Model
dependent
★
A2-04
Rated motor frequency
0.01 Hz to max. frequency
Model
dependent
★
A2-05
Rated motor speed
1 to 65535 RPM
Model
dependent
★
A2-06
Stator resistance
0.001 to 65.535 Ω (AC drive power ≤ 55 kW)
0.0001 to 6.5535 Ω (AC drive power > 55 kW)
Model
dependent
★
A2-07
Rotor resistance
0.001 to 65.535 Ω (AC drive power ≤ 55 kW)
0.0001 to 6.5535 Ω (AC drive power > 55 kW)
Model
dependent
★
A2-08
Leakage inductive reactance
0.01 to 6553.5 mH (AC drive power ≤ 55 kW)
0.001 to 655.35 mH (AC drive power > 55 kW)
Model
dependent
★
A2-09
Mutual inductive
reactance
0.1 to 6553.5 mH (AC drive power ≤ 55 kW)
0.01 to 655.35 mH (AC drive power > 55 kW)
Model
dependent
★
A2-10
No-load current
0.01 to A2-03 (AC drive power ≤ 55 kW)
0.1 to A2-03 (AC drive power > 55 kW)
Model
dependent
★
A2-37
Auto-tuning selection
0: No auto-tuning
1: Asynchronous motor partial static auto-tuning
2: Asynchronous complete dynamic auto-tuning
3: Asynchronous complete static auto-tuning
0
★
A2-38
Speed loop
proportional gain 1
1 to 100
30
✩
A2-39
Speed loop integral time 1
0.01s to 10.00s
0.50s
✩
A2-40
Switchover frequency 1
0.00 to A2-43
5.00 Hz
✩