D. Color adjustment:
1. Setup input timing ICL-605, white pattern.
2. Confirm auto color adjustment had already done.
3. Measure color temperature by Minolta CA-210 (or equivalent equipment).
4. Check the color temperature Bluish, Reddish & Normal. The color temperature
specification as follows:
<For 300 nits>
Color mode
Color temperature
x
Y
Normal
6500k
0.313±0.020 0.329±0.020
Min 180cd/m
2
Bluish
9300k
0.283±0.020 0.297±0.020
Min 160 cd/m
2
Reddish
5800k
0.326±0.020 0.342±0.020
Min 180 cd/m
2
User Mode
Panel default color temp.
Min 200 cd/m
2
sRGB
6500k (Gamma=2.2±0.2) 0.313±0.015 0.329±0.015
200 ± 20 cd/m
2
5. Setup input timing, 32 -Gray pattern.
To check if there are any abnormal display problems of preset timing modes.
6. Checking if the picture is no good, reject this monitor.
7. To chec
k the power consumption by disabling “burn-in mode” setting
8. To clear user data and program complete DDC data to monitor by IIC bus communication.