4.3. Alignment procedure (for function adjustment)
A. Preparation:
1.
Setup input timing ICL-605(800x600@60Hz), Pattern: 5-Mosaic.
2.
Setup unit and keep it warm up at least 30 minutes.
B. Timing adjustment:
1.
Enter factory setting area (press “ENTER”, “MENU” and then press “SOFTPOWER”).
2. Check the settings to following values:
Contrast = 50
Brightness = 100
Color temp = User Mode
Picture mode = User
Language = English
Burn In =ON
Then, turn off the monitor power.
3. Turn on power enter user area.
C. Color balance adjustment:
1.
Enter factory setting area (press “ENTER”, “MENU” and then press “SOFTPOWER”).
2. Setup input timings (800x600@60Hz), Pattern: 5-Mosaic.
3. Setup Picture mode = User then Color temp = User Mode.
4. Open Factory page then select
“AUTOCOLOR or White Balance” item and press “ENTER”
button to do auto color.