background image

Bennett Pulser Assembly Instruction Manual 

Installation Instructions 

SECTION 3: INSTALLATION INSTRUCTIONS 

Bennett Pump Dispensers are to be installed by trained technicians. All technicians must be aware of ALL safety instructions. If you are 
not a Bennett trained technician, please contact Bennett Technical Support at 1-800-423-6638 for training information. 

HOW TO REMOVE PULSER COVER 

Remove the Pulser cover and set aside. Retain screws for reuse.  

Note:  

 

After installation is complete, replace cover using the screws provided.   

 

The “Sealed” pulser cover shown below is optional.  If it is present, please check the requirements by the AHJ to put the pump 
back into service. 

 

 

 
 
 

HOW TO MOUNT THE PULSER ASSEMBLY  

The Pulser Assembly measures 4” x 2” x 2””. Each Pulser requires two mounting screws for the mount, and 2 mounting screws for the 
cover to the mount. 

1.

 

Mount Pulser by aligning roll pin in coupler slot.   

2.

 

Mount bracket screws to the top of the meter cover using the screws provided. Tighten firmly. 

3.

 

After the pulser is mounted and installation is complete, replace cover and seal if necessary.  

 

HOW TO CONNECT PULSERS 

CAUTION:  WHEN CONNECTING A PULSER NEVER CONNECT A PULSER OR DISCONNECT A PULSER WITHOUT TURNING OFF 

THE DISPENSER POWER AND BATTERY. DAMAGE TO THE PULSER OR THE LOWER I/O BOARD CAN OCCUR IF 
POWER IS LEFT ON.
 

MOUNTING HOLE 

MOUNTING HOLE 

1.

 

Seal Wire is Thread thru the 
Meter Collector cover bolts, 
then up to the bolt 
connecting the cover to the 
meter top. 

2.

 

The seal wire then threads 
from the pulser cover through 
the standoffs holding the 
pulser 

3. After the Seal Wire is thread 
through both pulser mounting 
standoffs, is routed back down to 
the Meter mounting adaptor. 

Summary of Contents for PULSER

Page 1: ...2020 Only Trained Personnel May Work on This Equipment READ THIS MANUAL This manual has important information for safe installation and operation of this equipment Read and understand this manual befo...

Page 2: ...outside USA 231 798 1310 Extension 287 or 269 Customer Service USA 231 719 6050 Facsimile USA 231 799 6202 Email sales bennettpump com or salesintl bennettpump com Website www bennettpump com For new...

Page 3: ...f Bennett Products 4 Abbreviations and Acronyms 4 SECTION 2 PRODUCT INTRODUCTION 5 Features 5 Specifications 5 Pulser Assembly 6 SECTION 3 INSTALLATION INSTRUCTIONS 9 How to Remove Pulser Cover 9 How...

Page 4: ...Bennett Pulser Assembly Instruction Manual Table of Contents ii Page Intentionally Left Blank...

Page 5: ...submerged pump before working on it Maintenance repairs must be done by authorized personnel only Warranty work may only be performed by Bennett certified technicians To prevent electric shock keep th...

Page 6: ...NFPA 30A Motor Fuel Dispensing Facilities Standard NFPA 70 National Electric Code International Fire Code 2018 Edition Weights Measures Handbook 44 UNAUTHORIZED ALTERATION OF BENNETT PRODUCTS DANGER...

Page 7: ...Barrier Boards are covered by a plastic cover Always replace the cover after servicing the equipment SPECIFICATIONS Electrical Ratings Operating Voltage 5 0 25 VDC Supply Current 30mA Max 5 VDC Logic...

Page 8: ...uction Manual Product Introduction 6 PULSER ASSEMBLY PULSER ORIENTATIONS ITEM DESCRIPTION 1 Pulser Mount 2 Pulser 3 Circuit Board Assembly Pulser 4 Top Cover Pulser Assembly 3 1 2 Top View Side View M...

Page 9: ...Pulser B Phase 2 Bi Directional 9 Pulser C Phase 1 Bi Directional 10 Pulser C Phase 2 Bi Directional 11 Pulser D Phase 1 Bi Directional 12 Pulser D Phase 2 Bi Directional 13 Connection Verification Bi...

Page 10: ...Bennett Pulser Assembly Instruction Manual Product Introduction 8 Page Intentionally Left Blank...

Page 11: ...2 Each Pulser requires two mounting screws for the mount and 2 mounting screws for the cover to the mount 1 Mount Pulser by aligning roll pin in coupler slot 2 Mount bracket screws to the top of the...

Page 12: ...d if applicable pulsers for side 2 connect to J1 on the Lower I O Board Note The ribbon cable has notches so the cable cannot be put on backwards Pulser for Product A plugs directly into the Lower I O...

Page 13: ...draulics area low voltage section of the dispenser The ribbon cable connects to pulser connector J2 to the first pulser in the loop Usually this is the A product If there is more than pulser then anot...

Page 14: ...s by mail email phone fax or web using the information provided below Note Verbal orders cannot be accepted A signed purchase order must be faxed or emailed to the Bennett Order Entry Department at 23...

Page 15: ...Bennett Pulser Assembly Instruction Manual Diagnostics Troubleshooting 13 Page Intentionally Left Blank...

Page 16: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 14 SECTION 5 WIRING DIAGRAMS...

Page 17: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 15...

Page 18: ...Bennett Pulser Assembly Instruction Manual Page Intentionally Left Blank...

Page 19: ...Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Reviews: