Bennett Pulser Assembly Instruction Manual
Diagnostics & Troubleshooting
12
SECTION 4: DIAGNOSTICS & TROUBLESHOOTING
This section describes the information provided on each diagnostic display message. Note: Displays shown throughout the manual are
examples only. Information may vary based on dispenser options.
DIAGNOSTICS
Error checking - The dual phase pulsers allow for error checking. One phase is used to check the other. For example, after pumping 1 gallon
of fuel the CPU should see approximately 1024 pulses from each phase. There is a built in diagnostic where if the CPU sees more than 26
consecutive missing pulses from one or the other of the phases it will stop the sale and post an error message on the display of the side of
the dispenser with the error. Errors are stored in a diagnostic history file and any error that occurs can be cleared by removing and replacing
the nozzle from the nozzle boot, or lifting and lowering the lever if it is set up in the Lever Option.
TROUBLESHOOTING
HOW TO PLACE AN ORDER FOR PARTS
To place an order for parts please contact us by mail, email, phone, fax, or web using the information provided below. Note: Verbal
orders cannot be accepted. A signed purchase order must be faxed or emailed to the Bennett Order Entry Department at 231-799-6202
or
. For new manuals, visit our web page at
Bennett Pump Company
Marketing Services
1218 East Pontaluna Road
Spring Lake, MI 49456
Telephone from USA 1-800-235-7618
Telephone from outside USA 231-798-1310, Extension 287 or 269
Customer Service USA 231-719-6050; Facsimile USA 231-799-6202
Email:
Website:
ALL ORDERS MUST INCLUDE THE FOLLOWING INFORMATION:
Note:
Many electronic circuit boards have a factory-rebuilt equivalent. All rebuilt boards have a part number prefix of “RB”. Please
refer to the Distributor Policy Manual for program terms and details.
1.
The part number, description, and quantity are required.
2.
The complete “ship to” address.
3.
Your company’s name and address (if different from the shipping destination) for billing purposes
.
PROBLEM
CAUSES/SOLUTIONS
Pulser showing Disconnected from electronics
Verify that the jumper Is in the last pulser in series, connector J3
Verify the pulser is connected to the electronic circuit board
Summary of Contents for PULSER
Page 4: ...Bennett Pulser Assembly Instruction Manual Table of Contents ii Page Intentionally Left Blank...
Page 16: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 14 SECTION 5 WIRING DIAGRAMS...
Page 17: ...Bennett Pulser Assembly Instruction Manual Wiring Diagrams 15...
Page 18: ...Bennett Pulser Assembly Instruction Manual Page Intentionally Left Blank...