27
EN
2ch
The second radio channel is enabled or disabled on terminals SCA (fig.2).
On: SCA output, preset as second radio channel. The
SERL
logic should be OFF.
Off: AUX output can be preset as SCA, or by SERL logic (the programming of a radio control in
the RADIO 2CH menu allows for the pedestrian passage opening).
(OFF)
serL
The service light function to output SCA (Fig.2) is enabled or disabled.
On: At every operation, the contact is closed for the time preset with
TLS
parameter Use the
auxiliary relay to control the light. 2CH logic should be preset on OFF.
Off: AUX output can be preset as SCA, or by 2CHlogic.
(OFF)
TST1
The test of photocells to PHOT O input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed.
Off: Test is disabled.
(OFF)
TST2
The test of photocells to PHOT C input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed.
Off: Test is disabled.
(OFF)
PHcl
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the photocell is re-
leased, the motor restarts in the opening phase.
In closing phase: the contact opening causes the motor stop. When the photocell is released,
the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the immediate reversion
of the operation direction (open).
(OFF)
SPN
The pickup function is enabled or disabled.
On: Enabled pickup. At the beginning of every operation, the motor operates at maximum
torque for 2 sec.
Off: Start-ups are at braked speed for 2 seconds. Then the system speeds up to standard
speed.
(ON)
MINV
The opening direction of the motor is selected (see Fig. 17):
On: Right side motor mount
Off: Left side motor mount
(OFF)
BAR
Changing the operating mode of the PHOT OPEN and BAR inputs in the event the sensitive edges
are installed on the mobile opening and closure edges (see Fig.18).
On: The PHOT OPEN input assumes a similar function to the BAR input, but inverts motion for
3s only during the opening phase. The edge connected to the BAR input is only active during the
closure phase.
Off: Intervention of the sensitive edge connected to the BAR input stops movement of the door
and inverts for approx. 3s, both opening and closure.
The PHOT OPEN input re-starts functioning of the photocell active on opening.
(OFF)
REM
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE
LEARNING).
On: Enabled remote storage
Off: Disabled remote storage.
(ON)
RADIO (
RADi
)
MENU
FUNCTION
PP
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step function.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
2Ch
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second radio channel.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
PED
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the PED function.
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
CLR
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
RTR
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
NUMBER OF CYCLES (
Nman
)
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
Summary of Contents for YAK 20 OM 115
Page 2: ...2 ...
Page 3: ...3 1 2 325 250 570 195 149 A B 143 33 3 3 5 m m 2 2 0 m m 7 0 m m 5 0 m m C ...
Page 4: ...4 3 4 B F T V Z R ...
Page 5: ...5 5 7 2 mm 6 P S M C ...
Page 6: ...6 8 11 9 10 GND L N C L ...
Page 11: ...11 OPEN OPEN OPEN OPEN MINV On MINV Off 17 BAr On OPEN PHOT OP BAR 18 ...