Operation Manual
EL512.256-H3 Series Display
Beneq Oy
Olarinluoma 9
Tel. +358 9 7599 530
VAT ID FI19563372
FI-02200 Espoo
Fax +358 9 7599 5310
www.beneq.com
Finland
www.lumineq.com
Date: February 13, 2017
Document number: ED000818B
Page | 12
6
Operational specifications
6.1
Environmental
Table 7. Environmental characteristics
Temperature
Operating
–25 °C …+65 °C
Non-operating
–40 °C …+75 °C
Operating survival
–40 °C …+65 °C (no permanent damage)
Test duration 24 h at temperature extremes (without condensation)
Humidity
Relative humidity
+40 °C, 93% RH, operating (IEC 60068-2-78)
Damp heat
+25 °C …+55 °C, 95% RH, non-operating
(IEC 60068-2-30)
Altitude
Operating
15,000 m (50,000 ft.) above sea level
Vibration
20…500 Hz
ASD level 0.05 g
2
/Hz
Random vibration wide band
IEC 60068-2-64, Test Fdb
Shock
Magnitude
Duration
Number of shocks
100 G
4 ms (half sine wave)
18 (3 on each of the 6 surfaces)
IEC 60068-2-27, test Ea
6.2
Reliability
MTBF > 30,000 h @ 25 °C
6.3
Safety
The display will not inhibit the end product from obtaining the following specification: UL544.