64
Bend-Tech Dragon A150
Troubleshooting Guide
Operator Control Panel
14
Ethernet Jack LED Lights
There are two lights at the port where the Ethernet cable connects to the ESS board. Knowing
the meaning and behavior of each color of the status lights can help the Operator diagnose
connection problems between Mach3 and the DragonA400.
ESS Board Status Lights
Light
Status
Definition
Solution
Red Left
On
Machine is in emergency state
(machine disabled)
Check E-stops
Red Right
Not used
N/A
N/A
Green Left
Rapid flashing
ESS/PC communication
N/A
Green Right
Two quick blinks
Waiting for communication with Mach3
This could be a normal
delay in communication
or it could be an issue
with connectivity.
One second on, one
second off
BootP mode
Remove the small
plastic jumper from the
BootP pins (JP1) and
power cycle the ESS.
One long flash, two short
flashes
The ESS board has lost its IP address
Run Configurator to
generate IP address
and power cycle the
ESS board.
Constant on
ESS mode - ESS has established
communication with the computer.
This is normal operating mode.
N/A
Ethernet Jack LED
Amber Link Light
On
Cable is connected to a device (the computer)
Off
No connection - bad cable or Ethernet
disabled on computer
Green Data Light
Flashing
Ethernet connected
Summary of Contents for DRAGON A150
Page 1: ...A150 Part 1 of 1 Maintenance Troubleshooting Revision 1 English 2020 Bend Tech LLC...
Page 12: ...xii Bend Tech Dragon A150 Troubleshooting Guide Contents...
Page 28: ...28 Bend Tech Dragon A150 Troubleshooting Guide Toolhead 03...
Page 34: ...34 Bend Tech Dragon A150 Troubleshooting Guide Torch 04...
Page 36: ...36 Bend Tech Dragon A150 Troubleshooting Guide Engraver 05...
Page 38: ...38 Bend Tech Dragon A150 Troubleshooting Guide Marker 06...
Page 44: ...44 Bend Tech Dragon A150 Troubleshooting Guide Gate 08...
Page 48: ...48 Bend Tech Dragon A150 Troubleshooting Guide Trolley 09...
Page 56: ...56 Bend Tech Dragon A150 Troubleshooting Guide X and Y Axis Maintenance 11...
Page 72: ...72 Bend Tech Dragon A150 Troubleshooting Guide Limit Switch Operation 15...
Page 77: ......