Benchmark Scientific Incu-Shaker CO2 Mini Operating Manual Download Page 3

 

 

1. General Information and Precautions 

 

Safety Symbols: 

 

 

 

 

 

1.1. Precautions related to the power cable 

Always allow at least 3cm between the power cable and the back wall to prevent the back wall from causing 

pressure on the power cable. 

 

Always use the electrical plug that was supplied with this instrument.   

 

            

Never touch the power cord with wet hands. (This can result in electric shock.) 

 

Never use a damaged power cord or power outlet. 

 
 
In the event of smoke or a burning smell, immediately remove the power cord from the outlet. 

 

 

 

 

1.3. Precaution for use 
 

Do not attempt to disassemble this instrument.  If service is required, please contact your local 
representative. 

 

 

Never operate a flammable spray near this instrument. (This can result in a fire hazard.) 

 

 

Always use caution when using flammable substances such as benzene, alcohol 

and LP gas.    (Failure to do so can result in a fire hazard.) 

 

Prevent foreign substances from contacting the door seal. (The inflow of outside  air can negatively 

impact the temperature in chamber.) 

 

  Permissible ambient temperature range for transport: -10

 

to 60

.

 

 

 

Summary of Contents for Incu-Shaker CO2 Mini

Page 1: ...1 OPERATING MANUAL...

Page 2: ...Table of Contents NO CONTENTS PAGE 1 SAFETY AND GENERAL PRECAUTION 3 4 2 FEATURES AND SPECIFICATIONS 5 3 CONTROL PANEL 6 4 INSTALLATION 7 5 CO2 INCUBATOR OPERATION 8 11 6 ORBITAL SHAKER OPERATION 11 1...

Page 3: ...he event of smoke or a burning smell immediately remove the power cord from the outlet 1 3 Precaution for use Do not attempt to disassemble this instrument If service is required please contact your l...

Page 4: ...0cm from the back wall Install the unit in the way that the power plug is easily accessible and can be easily pulled in case of danger Install the instrument on a flat and stable surface free from vib...

Page 5: ...Microprocessor On Off Control Humidity 70 80 at 37 CO2 Range 0 to 20 Accuracy 0 1 at 5 at 37 setting CO2 Increment 0 1 CO2 Sensor IR CO2 Sensor Shaker RPM 30 to 300 rpm RPM Accuracy 1 Increment 1 RPM...

Page 6: ...6 Shaker Status Pilot Lamp When Shaker is running this lamp is flashing 7 Alarm On Off Switch 8 Alarm Mute Button When pressed provides a10 minutes audible alarm delay 9 Heating Signal Shows the stat...

Page 7: ...cold air Direct sunlight An uneven surface or table A place with heavy vibration A place with little air ventilation space behind the incubator 4 2 Place the shelves and water container as shown in ch...

Page 8: ...t the desired value of Co2 density by adjusting UP or DOWN key c Press SET key again after inputting the value SAVE is shown up on LED screen as below Note Always press the SET CO2 key after adjusting...

Page 9: ...th channel the LED is back to temperature display b Second Calibration Setting Outer Door Temperature The purpose of this heater is to prevent water condensation from forming on the glass door caused...

Page 10: ...ay shows 4 then press up to set to 1 e Fifth Calibration Setting Heating control NOTE Channel 5 is to set heating control point and is designed to prevent a significant temperature overshoot This mode...

Page 11: ...nces So set the temperature at 5 higher than operating temperature or desired point If the SAFETY LED on the front panel is illuminated this switch has been activated and is limiting the temperature 6...

Page 12: ...humb screws 6 4 Shaker Error Message 1 This message rErrL represents a low speed speed error Check the platform to ensure that nothing is obstructing it s movement Check the set speed to make sure tha...

Page 13: ...l number label of the machine 5 Defective power switch check voltage at switch 6 5 Disconnecting inside Shaker Connector of the orbital shaker is located at upper right back wall of chamber see below...

Reviews: