The LED
1
on the sensor board
2
should be on until the elevator lift rod
3
raises to its upper
limit. The sensor LED
1
should then turn off when the elevator lift rod
3
lifts up beyond the
sensor. The output of the sensor board
2
should then transition high (+5V). If the LED
indicators do not illuminate, or the output does not transition high when the elevator rod lifts
beyond the sensor, check the power and connections to the sensor boards. If OK, you may
have a bad sensor.
Elevator does not lift
•
Check to see that the dip switch setting for Auto Playfield Floor Adjustment is enabled.
•
Check connections and continuity to elevator lift motor
Game will not enter Program Mode
•
The game has partial credit on it. Insert more coins until you reach full credit and try again.
No Power Inside Game
•
Bad power cord
o
Try another power cord
•
Blown power input fuse(s)
o
Follow instructions for ‘Replacing Power Input Fuses’ in Repair and Maintenance
section of this manual