5
INSTALLATION TYPE A
These diagrams detail the installaon of the appliance into a standard 16” x 22” opening.
This method of installa1on is suitable for both Class 1 and Class 2 installa1ons.
This installaon requires a
900 STANDARD MANTEL.
For crical dimensions see page 8.
The
900 FIXING PLATE
supplied is firmly
aPached to the builders opening aer
the hearth has been installed. Screws
and rawl plugs are provided for this
purpose.
For
minimum
hearth
requirements see page 8.
Using mortar or fondue around the
inside edge of the plate/builders
opening this
900 FIXING PLATE
should
be sealed and fixed into place as if it
were a marble back panel. It is
important that no leakage should
occur. See further details on page 14.
Furthermore
a
suitable
high
temperature masc should be used to
further seal around the outside edge of
the
900 FIXING PLATE
and the wall.
The
TYPE
A
INSTALLATION
is
completed by installing the
900
STANDARD MANTEL
to
the
wall
securely. The mantel should be centred
around the FIXING PLATE.
The crical dimensions of the
900
STANDARD MANTEL
are detailed on
page 8. These crical dimensions
ensure that the front trim plate of the
fire and the front face of the mantel
are aligned.
The front trim plate of the appliance is
fully adjustable with four independent
magnets. These magnets can be
screwed in or out to posion the front
trim plate correctly. This adjustment is
provided as there may be some
variaon in the wall flatness and level.
See page 17 for full details regarding
front trim installaon and adjustment.
Ensure the hearth is set level before con1nuing with
the installa1on. Failure to install a level hearth could
affect the installa1on of the mantel and appliance.