22

23

SIDE CONTROL PANEL

WARNINGS

Side Control Buttons

 

Use side control buttons  
on unit when remote  
control is broken or its 
batteries are dead

 

Press “Cleansing” or  
“Bidet” to start. 

 

Press again to stop. Do 
not use sharp items to               
press buttons. 

Do not drop the remote control in water.  
It may cause out of order malfunction.

All functions will be operational when the seat is  
occupied except Nozzle Cleaning and Power/Economy. 

Before operating, ensure that the water tank is  
filled up completely. 

Beeping 

 

Press “Beeping” to enable the beeping sound. 

 

To disable, press the button again.  

Water Pressure

 

Water spray pressure can be adjusted in 5 levels by  
pressing (HI)(LO) buttons. 

 

Set water pressure level will remain.  

Nozzle Position

 

Nozzle position can be adjusted in 5 levels by pressing (FR)/(BK) buttons. 

 

Set nozzle position will remain.  

Economy

 

Press “Stop” button for 3 seconds to activate the power saving function.

 

Economy function will be disabled once user sits on bidet.  

*When the power cord is plugged in initially, nozzles for feminine wash and 
posterior will come out in turn. 

*All the operating times indicate are approximate. 

Summary of Contents for bioBidet UB-4800

Page 1: ...OWNER S MANUAL UB4800 ...

Page 2: ...ns 13 Product Information 14 PRODUCT INSTALLATION Seat Installation Guide 13 Water Connection Guide 17 Testing Seat Bumpers 18 Remote Installation Guide 19 PRODUCT OPERATION How to use 20 Side Control Panel 22 Warnings 23 Cleaning 24 Maintenance 25 Troubleshooting Guide 29 WARRANTY Warranty 30 ...

Page 3: ... Adjustable heated seat Pulsating Kids wash Massage cleaning Intelligent body sensor Satisfying posterior cleaning Splash guard Soft feminine cleaning Slow closing seat lid Adjustable nozzle Quick release for easy cleaning Nozzle self clean Automatic power save ...

Page 4: ...ed into a tub or sink Do not place in or drop into water or other liquids Do not touch a product that has fallen into water Unplug immediately WARNING To reduce the risk of burns electric shock fire or injury Close supervision is necessary when this appliance is used by or is near infants elders or handicapped persons Children should not be permitted to use or touch this appliance without adult su...

Page 5: ... or if you do not know whether the product is properly grounded This product is for use on a nominal 120V circuit It has a grounding plug that looks like the plug illustrated in sketch A A temporary adapter which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2 pole receptacle as shown in sketch B if a properly grounded outlet is no available The tempo...

Page 6: ...s appliance Doing so may result in fire or electric shock Use tap potable water only ground water Not doing so may cause irritation or injury Do not step on or place heavy objects on this appliance Doing so may damage the unit or result in malfunction of the appliance Be aware of urine splash on nozzle Doing so may result in malodor or failure of appliance Do not sit or lean against the lid or con...

Page 7: ...12 13 PARTS 15mm Water supply hose 2pcs DIMENSIONS The toilet dimensions must be within those shown above Do not install this appliance on a toilet that does not meet those dimensional requirements ...

Page 8: ... Thermal switch Temperature fuse Floating switch Heated seat Seat temperature Room temp 104 F 40 C Heater capacity 55W 15 Safety feature Temperature fuse Circuit breaker Within 15mA 0 03 seconds Length of power cord 1 2m Dimensions W 407 mm X L 532mm X H 170mm W 16 02 in X L 20 94 in H 6 69 in Weight 4 16kg 9 17lbs INSTALLATION 1 3 3 2 2 4 5 6 1 6 5 4 Mounting Plate Cone packing Washer Nut Mountin...

Page 9: ...y hose 1 2 to 1 2 Optional 1 2 Spare Nut Available by request To the unit Main unit Connect the other end of the water supply hose 1 2 to 1 2 from the T valve to the main unit Open the shutoff valve by turning it counter clockwise Check for any water leaking or dripping Using an Inline Carbon Filter The use of an external inline carbon water filter is not required unless the unit is used in an are...

Page 10: ...s a gap between the toilet base and toilet seat If necessary place the bumpers on the underside of your toilet seat as indicated above Open the battery lid and inster AAA batteries 3pcs Remember to place the remote in a spot you can easily reach while seated Fasten the remote control bracket with double sided adheasive tape on the proper area of the wall as shown CAUTION Use AAA batteries Do not u...

Page 11: ...n cleansing area Oscillation wash stops if this button is pressed again Kids Press Kids to change all functions to be suitable for children 1 minute for oscillation level 1 of water pressure and level 5 of nozzle position This unit should be used under the supervision of an adult Water Seat Temperature Adustment Press Water Temp while on or off the unit Press again to adjust water temperature to 9...

Page 12: ...ater tank is filled up completely Beeping Press Beeping to enable the beeping sound To disable press the button again Water Pressure Water spray pressure can be adjusted in 5 levels by pressing HI LO buttons Set water pressure level will remain Nozzle Position Nozzle position can be adjusted in 5 levels by pressing FR BK buttons Set nozzle position will remain Economy Press Stop button for 3 secon...

Page 13: ...t FR or Back BK button for 3 seconds to extract posterior nozzle Press Stop button to retract nozzle Use a toothbrush or soft cloth to clean nozzles Press Stop and nozzle will return to stand by mode STRAINER MAINTENANCE This appliance will not operate properly if the strainer is clogged Be sure to clean the strainer regularly Close the shutoff valve by turning it clockwise Unscrew the nut Clean t...

Page 14: ...water by unscrewing the drain bolt from the closed position Do not lose the drain bolt The following figure is only to check the location of Drain Bolt To prevent malfunction do not place the vertical positionor tilt the product Screw drain bolt back to closed position and reinstall the unit Refer to the trial operation procedure before using the appliance again Close the shutoff valve 1 Unplug th...

Page 15: ... hoses tightened up properly If water is still leaking or dripping contact your dealer Seat or water is not warm enough Is the temperature set to OFF Is the appliance used in eco mode during cold weather Reset the temperature Press eco again to release the function PREVENT FREEZING Make sure the power cord is properly plugged in Set the water temperature to low or middle Freezing can be prevented ...

Page 16: ...e or loss resulting from sediment or other matters contained in your water system This warranty gices you specific legal rights For warranty or service information please contact your dealer whereyou bought this appliance or us Only the original purchaser may submit a claim under this limited warranty This limited warranty is our only warranty covering your product Repair or replacement as provide...

Page 17: ...Technical Support Customer Service 7900 S Route 31 Crystal Lake IL 60014 T 847 458 2334 U S TOLL FREE 877 339 5214 support biobidet com www biobidet com Thank You ...

Reviews: