LR1100 Programming Manual V1.2
[Type ID] (n=2)
Bit
Off/On
Hex
Decimal
Contents
0
Off
00
0
Multi-byte code characters not supported
On
01
1
Multi-byte code characters supported
1
On
02
2
Auto cutter Installed.(Fixed)
2,3
-
-
-
Not used
4
Off
00
0
Fixed
5
-
-
-
Not used
6
-
-
-
Not used
7
Off
00
0
Fixed
GS
(
H pl pH fn m d1 d2 d3 d4 (fn=48)
[Name]
Set the process ID response
[Format]
ASCII GS ( H pl pH fn m d1 d2 d3 d4
Hex 1D 28 48 pl pH fn m d1 d2 d3 d4
Decimal 29 40 72 pl pH fn m d1 d2 d3 d4
[Range]
(pl+pH
×
256)=6 (pl=6,pH=0)
Fn=48,m=48
32
d
126
[Description]
Saves the process ID specified by (d1,d2,d3,d4)for the data processed immediately
before this function.
GS H n
[Name]
Select printing position for HRI characters
[Format]
ASCII GS H n
Hex 1D 48 n
Decimal 29 72 n
[Range]
0
n
3, 48
n
51
[Description] Selects the printing position of HRI characters when printing a bar code. n selects the
printing position as follows:
n
Printing position
0, 48
Not printed
1, 49
Above the bar code
2, 50
Below the bar code
3, 51
Both above and below the bar code
[Notes]
HRI indicates Human Readable Interpretation.
HRI characters are printed using the font specified by GS f.