Parts List Drawing Insert Page 

Title:   

Model:  

Item Number:   

Wiring Diagram: 

Ventless Donut Kiosk (Insider) 

INSIDER ASSY FOR MK

208-240V 60HZ 1PH

 

2288

8

-20  Insider Assy for MK

V

 208-240V 60HZ 1PH 

IN-

1736 R02

 Electrical Assembly Drawing (IN-1739)

 

Belshaw-Adamatic

 www.belshaw.com 

 Phone 206-322-5474 

 1-800-BELSHAW 

9-30-20

 Ventless Donut Kiosk (Insider)

 

Summary of Contents for 22587-20

Page 1: ...ce for Donut and Bakery Equipment www belshaw com USA Canada 1 800 578 2547 International 1 206 322 5474 Email service belshaw com Web www belshaw com SERIAL NUMBER ITEM NUMBER VentlessDonutCenter Ins...

Page 2: ......

Page 3: ...ght claim with the shipping company immediately EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine Purchased by ______________________________________...

Page 4: ...R DONUT FRYING SYSTEM COMMERCIAL ELECTRIC COOKING APPLIANCE WITH INTEGRAL RECIRCULATING SYSTEM INSTALLATION REQUIREMENTS INSIDER SPECIFICATION SHEET FIRE SUPPRESSION DESCRIPTION INSTALLATION INFORMATI...

Page 5: ...to another The Insider includes an built in air recycling system and no exterior ductwork is necessary The Insider is designed to attract the interest of passers by With its large window viewing area...

Page 6: ...rlock system to ensure ventilation is active Fryer is otherwise shut down or unable to start Donut Robot fryer specify model from list below and Roto Cooler Fire suppression system Pyro Chem Kitchen K...

Page 7: ...ection for restaurant cooking appliances hoods and ducts The Pyro Chem System PLC 240 300 KITCHEN KNIGHT II utilizes a wet chemical agent specifically designed to suppress restaurant cooking fires The...

Page 8: ...e with NSF International Standard No 4 One of the above models is used in each Insider Materials employed have been found to be able to withstand normal wear penetration of vermin corrosive action of...

Page 9: ...cordance with a The Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 96 b The National Electrical Code ANSI NFPA 70 and c Other codes such as the Internationa...

Page 10: ...ividual appliance shall be considered as occupying not less than 100 square feet 9 3 m2 3 Net exhaust volumes for hoods shall be permitted to be reduced during part load cooking conditions where engin...

Page 11: ...ng the control head cover and removing the Fire Damper Safety Pin A signed and dated log of installation and maintenance must be kept on premises for use by authority having jurisdiction ETL UL NFPA S...

Page 12: ...nsider has been fire tested by UL ETL as a stand alone appliance and is not subject to change The ETL Listing does not allow it to be hardwired or permanently attached to the building structure The Re...

Page 13: ...Pyro Chem Data Sheet...

Page 14: ......

Page 15: ...r Filtration Hood and Fire Extinguishing System Operator s Manual Belshaw Bros Inc 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 E mail service belshaw com http...

Page 16: ...06 322 5474 Fax 206 322 5425 Insider OM MN 1852EN iii Contents 1 Operation 1 Startup Run 1 Shutdown 1 In Case of Fire 2 2 Cleaning 3 Cleaning 3 Hand Washing Instructions 4 Automatic Dishwasher Instruc...

Page 17: ...CERTIFIED PERSONNEL ON A REGULAR BASIS AND THE USE AND MAINTAINENCE OF THE INSIDER IS TO BE IN ACCORDANCE WITH NFPA 96 To avoid damaging the machine never use force to assemble disassemble operate cl...

Page 18: ...the Start button in for a few seconds while the proper airflow is attained 7 The system must be on to provide power to the air filtration system overhead lights auxiliary outlet fryer and cutter See M...

Page 19: ...u may activate it manually by pulling the handle on the silver manual pull station located at the back of the Insider to the right of the red fire suppression cylinder 3 Call the Fire Department 4 Per...

Page 20: ...heavily contaminated with grease or oily sludge They should be inspected at least once every month If a vent cleaning service is used a certificate showing date of inspection or cleaning should be mai...

Page 21: ...nd grease filter no longer feels slippery Automatic Dishwasher Instructions 1 Put the air cleaner cell on the lower rack of the dishwasher with the airflow arrow pointing up It maybe necessary to remo...

Page 22: ...ing in the cell This will cause no harm and the sound will quit when the cell has dried Cleaning Windows Sliding Doors 1 Use a mild liquid dishwashing soap and a soft cloth or sponge 2 Dry with soft c...

Page 23: ......

Page 24: ...Filtration Hood and Fire Extinguishing System Technical Supplement Belshaw Bros Inc 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 E mail service belshaw com http...

Page 25: ......

Page 26: ...ck Check Inspections 6 Use and Maintenance 6 Fire Suppression System 6 Fire Damper System 13 Carbon Filters 14 Electronic Air Cleaner 14 3 Troubleshooting 15 Troubleshooting 15 1 Insider will not run...

Page 27: ...CERTIFIED PERSONNEL ON A REGULAR BASIS AND THE USE AND MAINTAINENCE OF THE INSIDER IS TO BE IN ACCORDANCE WITH NFPA 96 To avoid damaging the machine never use force to assemble disassemble operate cl...

Page 28: ...WARNING To avoid electrocution or other injury turn off the machine s main power before attempting any cleaning disassembly adjustment or repair NOTICE IN CASE OF FIRE Instructions for manually opera...

Page 29: ...the Mark II V or IX Fryer assembly on the cabinet top and place over the locating pins This properly locates the fryer under the fire suppression nozzles 4 Remove the protective paper and the vinyl fr...

Page 30: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Insider TS MN 1853EN 3...

Page 31: ...e inside interlock switch There is a 1 diameter disc that pushes against the top filter The disc and switch are adjustable if required to make the interlock function Shutting the door pushes the top f...

Page 32: ...s attached to the safety pin for identification Remove the safety pin to arm the damper release mechanism as shown in Illustration C DANGER To avoid causing death or serious bodily harm to building oc...

Page 33: ...nce inspections Use and Maintenance All filters shall be cleaned or replaced in accordance with the manufacturer s instructions The grease filter and pre filter should be cleaned daily The carbon filt...

Page 34: ...sert System Maintenance Storage Recharging supplies of wet chemical shall be stored in the original closed shipping container supplied by the manufacturer These containers shall not be opened until th...

Page 35: ...guishing systems shall be subjected to a hydrostatic pressure test at intervals not exceeding 12 years 1 Wet fire suppression cylinder 2 Auxiliary pressure container Exceptions 1 Auxiliary pressure co...

Page 36: ...or Installation Fusible links are always used in conjunction with the Model NMCH Mechanical Control Head After mounting the cylinder and control head the fusible link line can be installed The first s...

Page 37: ...ing the cable to mechanical components The crimp must never be used on a single cable The fusible link line can now be put into a set position by applying tension to the fusible link line This is acco...

Page 38: ...e cable The fusible link line can now be put into a set position by applying tension to the fusible link line This is accomplished by using a socket on the fusible link line ratchet wheel The ratchet...

Page 39: ...x and conduit feed the stainless steel cable from the releasing device through the conduit and into the pull station box Feed the cable through the bushing and through the hole provided in the pull ha...

Page 40: ...wrench to tighten the cartridge into the actuator Remove the pull pin from the hole in the slide plate and install the control head cover Fire Damper System Visually inspect the damper or damage and v...

Page 41: ...mount of dirt present in the air in you locality The washing frequency best suited for you unit can be determined by examining the dirt collected components at three 3 week intervals As the dirt begin...

Page 42: ...ou perform repairs yourself or have them performed by anyone other than Belshaw Bros or a service technician authorized by Belshaw Bros you do so at your own risk For factory service return your machi...

Page 43: ...ut Check fuses located inside electrical enclosure and replace If condition continues look for electrical short Fire suppression system has fired Call the Pyro Chem certified personnel to reset change...

Page 44: ...d properly or obstruction in filters air flow 1 Hold the Start button in for a few seconds to attain proper air flow 2 Check clean or replace filters 3 Check to see if reed switch is stuck Tap on swit...

Page 45: ...ge Connection Improper ground Loose Hi Voltage Connection Correct Correct Odor of Ozone Same See Page 25 4 Electronic Air Cleaner Symptoms and Corrections 1 Arcing Noise When an arcing noise is noted...

Page 46: ...This trouble is not common but when occurring is usually due to either a continuous high voltage leak or discharge or from the absence of a good common electrical ground Refer to checks listed under 1...

Page 47: ...etected visually Power Supply Check without high volt meter Problem Areas Corrections Excessive dirt build up Wash Large pieces of foreign matter lodged between plates Remove Very dirty insulators Cle...

Page 48: ...defective one will produce no arc at all or a very weak one Refer to illustration N Trouble shooting Trion power supply Power Supply Check with DC high volt meter Take reading with the high voltage m...

Page 49: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 22 MN 1853EN Insider TS...

Page 50: ...section please find information relating to Pyro Chem and Kitchen Knight Fire Suppression System In Case of Fire Pyro Chem Contacts Kitchen Knight II Owner s Manual for PCL 300 460 600 Pyro Chem Kitc...

Page 51: ...ted you may activate it manually by pulling the handle on the silver manual pull station located at the back of the Insider to the right of the red fire extinguisher cylinder 3 Call the fire departmen...

Page 52: ...x 206 322 5425 Insider TS MN 1853EN 25 To schedule a kitchen style fire suppression test United States Call Pyro Chem at 1 800 526 1079 Or visit their website at www pyrochem com and click on Key Cont...

Page 53: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 26 MN 1853EN Insider TS 5 Appendix Pyro Chem Kitchen Knight Manual Parts List Drawing Insert Page...

Page 54: ......

Page 55: ......

Page 56: ......

Page 57: ......

Page 58: ...ssy for MKII 208 240V 60HZ 1PH Final Assembly Drawing 22587 20 Final Assembly BOM Only Sub Assemblies IN 2008 Mechanical Assembly BOM Only IN 2008GCB Wiring Diagram IN 4021 Electrical Assembly Drawing...

Page 59: ......

Page 60: ...Number 22588 21 Insider Assy for MKV 208 240V 50HZ 1PH Final Assembly Drawing 22588 21 Final Assembly BOM Only Wiring Diagram IN 1737 Electrical Assembly Drawing IN 1737 1 Belshaw Adamatic www belsha...

Page 61: ......

Page 62: ......

Page 63: ......

Page 64: ......

Page 65: ...ssy for MKII 208 240V 60HZ 1PH Final Assembly Drawing 22587 20 Final Assembly BOM Only Sub Assemblies IN 2008 Mechanical Assembly BOM Only IN 2008GCB Wiring Diagram IN 4021 Electrical Assembly Drawing...

Page 66: ......

Page 67: ...agram Ventless Donut Kiosk Insider INSIDER ASSY FOR MKV 208 240V 60HZ 1PH 22888 20 Insider Assy for MKV 208 240V 60HZ 1PH IN 1736 R02 Electrical Assembly Drawing IN 1739 Belshaw Adamatic www belshaw c...

Page 68: ...ST LOCK 20A 250V HUBBELL 1 IN 0180 310 BLADE PLUG 250V 60A 3P4W VMI 1 MKV 0031 311 POWER DISTRIBUTION BLOCK MARATHON 1 TM634 0233 312 PHTM DIN RAIL 35MMX7 5MMX1FT 1 990 0260F 313 LABEL AUXILIARY 1 IN...

Page 69: ......

Page 70: ......

Page 71: ......