If there is primary power to the power supply and
the secondary output voltage is absent or very
low, the power supply is defective. Drawing an
arc, with an insulated handle screwdriver
between common ground and the high voltage
output terminal (c) can make a simple check. A
good power supply will produce a pronounced
arc where a defective one will produce no arc at
all or a very weak one.
(Refer to illustration “N” Trouble shooting
Trion-power supply).
Power Supply Check (with DC high volt
meter).
Take reading with the high voltage meter at cell
contact point. Voltage should read 7 kilovolts or
higher (without cell connected). If voltage is
above 7 kilovolts, the problem is in the cell (see
cell checkout procedure). If voltage is below 7
kilovolts (without cell connected), the problem is
in the power supply.
Proceed as follows:
Remove power pack from the unit.
Check for loose wires; if loose wire found,
reconnect.
If defective power supply is indicated, replace.
Summary of Contents for 22587-20
Page 2: ......
Page 13: ...Pyro Chem Data Sheet...
Page 14: ......
Page 23: ......
Page 25: ......
Page 30: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Insider TS MN 1853EN 3...
Page 49: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 22 MN 1853EN Insider TS...
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 59: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 66: ......
Page 69: ......
Page 70: ......
Page 71: ......