TROUBLESHOOTING
Servicing of the hotplates must only be done by an authorized service representative (see back of this booklet) and the hotplate
must not be modified. Power must be disconnected before any servicing or maintenance is conducted.
DO NOT MODIFY THIS APPLIANCE.
It is recommended the hotplate serviced by an authorized person at least every 2 years. This service is not covered by warranty.
Abnormal conditions include:
⚫
Excessively yellow or shooting flame type.
⚫
Flame lifting off the burner ports.
⚫
Flame lighting back into the burner (normally associated with a popping sound).
⚫
Objectionable odor of the
flame’s combustion products.
Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for possible causes
and remedies prior to contacting an authorized service representative. Servicing beyond the remedies listed shall only be
undertaken by an authorized service representative.
FAULT
POSSIBLE CAUSE
REMEDY
No spark when gas control
knob depressed.
No power.
Check plugged in and switched on.
Check mains circuit breaker.
Loose sparker cable.
Call authorized representative.
Burner not aligned properly.
Remove and re-fit burner.
Burner not lighting when
spark ignition working.
Gas supply off.
Check gas supply valve on.
Burner not aligned properly.
Remove and re-fit burner.
Burner ports blocked.
Remove, clean and replace burner.
Burner goes out when
control knob released.
Flame safeguard not activated.
Re-light, allow more time for flame safeguard
to activate.
Flame safeguard faulty connection or
broken.
Call authorized representative.
Uneven flame pattern or
slight flame lifting.
Burner ports blocked.
Remove, clean and replace burner.
At minimum flame setting
the flame is too high.
Turndown control setting incorrect.
Call authorized representative.
Small flame on High
setting.
Regulator faulty.
Call authorized representative.
Gas supply pressure low.
Call authorized representative.
Incorrect injector fitted.
Call authorized representative.
Blocked injector or gas supply tube.
Call authorized representative.
Incorrect utensil size.
Refer to operating instructions utensil choice.
Flame too high on High
setting.
Regulator faulty.
Call authorized representative.
Incorrect injector fitted.
Call authorized representative.
Incorrect utensil size.
Refer to operating instructions utensil choice.