Bellini BGT705X Installation & Operation Instructions Download Page 10

10 

Wiring diagram

 

4. Gas Connection

Install in accordance with relevant gas standards and/or codes of practice applicable.   

Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and 

manifold connection are in place and in good condition.   

For Natural gas: connect the natural gas appliance regulator (pictured opposite) with integral test point using

approved gas thread tape or compound to the elbow fitting.

For Universal LPG: see page 11

Ensure the supply connection point, test point and natural gas regulator adjustment 

screw (for Natural gas installation) are accessible for testing and/or adjustment with the 

hotplate in the installed position. Where a flexible hose assembly is 

used, ensure it is approved to AS/NZS 1869, Class B. Any hose 

assembly used must be restrained from accidental contact with the flue 

outlet of an under-bench oven. This hose assembly shall be suitable for 

connection to a fixed consumer piping outlet located as follows: 

Hotplates at a point 800 mm to 850 mm above the floor and in the 

region outside the width of the appliance to a distance of 250 mm. 

Note: 

Hose diameter 10mm, Length 1000mm (Maximum) 

After connecting to gas, check for leaks using soapy solution, never 

a naked flame. 

Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the 

inside of the cupboard door so it is clearly visible for any service technician.   

SETTING THE GAS PRESSURE:   

Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).   

Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and 

on again and recheck the pressure is same as set previously or adjust as required.   

TEST FOR CORRECT OPERATION:   

After installation and adjusting burner pressure using test point, each burner ignition and operation must be 

tested individually and with all burners operating. This testing must be done by the installer before leaving. 

Summary of Contents for BGT705X

Page 1: ...OPERATION INSTR UCTIONS 70cm Gas Cooktop Model No BGT705X BGT705X W BGT705X F V 8 AUG21 GSM Retail Australia Pty Ltd ABN 53 007 582 475 For Warranty and technical queries 1300 373 199 Aust OR 0800 76...

Page 2: ...retain your installation and user manual and receipt For all warranty and technical queries please contact Australia 1300 373 199 New Zealand 0800 764 912 GSM Retail Australia Pty Ltd ABN 53 007 582...

Page 3: ...ust be made by specialist installers to the legal and regulatory requirements in each country If the cable is damaged in any way it must be replaced by the manufacturer or after sale service or by aut...

Page 4: ...that are switched on Risk of burns Do not place objects made of metal such as knives forks spoons and saucepan lids on the cooking surface as they can get hot Special conditions which shall be avoided...

Page 5: ...th Any hose assembly used must be restrained from accidental contact with the flue outlet of an under bench oven How To Avoid Damage to The Appliance Do not use the cooking zones with empty cookware o...

Page 6: ...W 1R 2SR 1A With 2 types for option Front LPG 39 6MJ h NG 39 0MJ h Note For burner W Triple Ring Wok burner R Rapid burner SR Semi Rapid burner A Auxiliary burner NOTE On completion of the installatio...

Page 7: ...nto a surface where it can be read e g inside surface of adjacent cupboard 1 set Installation clip 4 sets Screws ST4 2x24 4 pcs LPG Injectors 4 pcs Elbow Washers 1 Elbow 3 washers Natural gas regulato...

Page 8: ...regulator and or flexible hose connection with the hotplate in the installed position Before the appliance is installed into the cabinet please make sure any transit protection is removed NOTE This ap...

Page 9: ...king Test burner ignition and burner flame for correct operation if burner is placed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the ignite...

Page 10: ...sembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the appliance...

Page 11: ...11...

Page 12: ...n MJ h WOK 1 70 13 0 WOK 0 98 13 0 Rapid 1 40 10 0 Rapid 0 90 10 0 SEMI RAPID 1 10 6 0 SEMI RAPID 0 7 6 3 AUXILIARY 0 90 4 0 AUXILIARY 0 55 4 0 Replacement of the nozzles must be performed by a qualif...

Page 13: ...as control knob for the burner to be lit to the High Flame setting Once again if problems with burner lighting persist refer to the TROUBLESHOOTING section of these instructions When burner lights adj...

Page 14: ...ive products Rinse with clean water Dry with a clean soft cloth BURNERS Remove trivets from hob Ensure burners are cool Remove the burners enameled cap C and aluminum burner crown F Wash down with war...

Page 15: ...ircuit breaker Loose sparker cable Call authorized representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply v...

Page 16: ...the Bellini product or it fails to perform to the Company s specifications as a result of some defect in materials components or workmanship Defect then the Company will at its option repair the Bell...

Page 17: ...any determines that it is defective through no fault of the Owner and is otherwise undamaged the Company will repair or replace the Bellini product in accordance with thiswarranty DO NOT SEND IN THIS...

Reviews: