7
INSTRUCTIONS FOR THE INSTALLER
Adjacent walls, cupboards and protection for
combustible materials.
Ensure that the appliance is installed in
accordance with clauses 6.2.5 and 6.10.1.1 of AS/
NZS 5601.1, or clauses 6.9.1 and 6.9.5 of
AS/NZS 5601.2 with regard to clearances
to combustible surfaces and materials, and
clearances to rangehoods and exhaust fans.
Clearance of 200mm from the periphery of burners
to vertical combustible surfaces is required.
Clearances to combustible surfaces may be
reduced only if combustible surfaces are protected
in accordance with clause 6.10.1.2 of AS/NZS
5601.1, or clause 6.9.2 of AS/NZS 5601.2.
The equipment must not be installed near
inflammable materials, such as curtains,
cloths,etc. Make a cut out in the benchtop, with
the dimensions indicated in fig.3, respecting a
minimum distance of at least 50 mm from the back
edge of the installed device and 100 mm of the
adjacent side walls.
MODEL
L (mm)
P (mm)
D (mm)
BDC604S
560
480
60
BDC905LS
805
480
60
Rangehoods and exhaust fans* shall be installed
in accordance with the manufacturer’s relevant
instructions. However, in no case shall the
clearance between the highest part of the hob
of the gas cooking appliance and a range hood
be less than 600mm or, for an overhead exhaust
fan, 750mm. (*An exhaust fan is defined as a
mechanical device other than a rangehood for
moving air from one interior space to another, or
to outside of the space)
IMPORTANT:
A separation panel at least 10mm from the
bottom of the cooktop must be included during
installation to prevent access to the underside
of the appliance. This panel can be made of any
non-combustible rigid material. Refer (fig. 4).
If the hob is going to be installed on the top of an
oven, precautions must be taken to guarantee an
installation in accordance with current accident
prevention standards. Pay particular attention to
the position of the electric cable and gas pipe: they
must not touch any hot parts of the oven.
Moreover, if the hob is going to be installed on
the top of a built in oven without forced cooling
ventilation, proper air vents must be installed to
guarantee
an
adequate
ventilation,
with
the
lower
air entering with a cross section of at least 200cm
2
,
and the higher air exiting with a cross section of at
least 60 cm
2
.
Fastening the top
Every cook-top is equipped with a special washer.
A
set
of
hooks
is
also
supplied
for
mounting
the
cook-top.
Depending
on
the
type
of
mounting
surface,
the
suitable type of mounting hook is supplied (hook A
or hook B).
For the installation proceed as follows:
–
Remove all loose components from the top.
–
Turn the appliance upside down lay it's edges on
foam packaging blocks to prevent damage to the
ignition spark plugs and lay the seal S along the
external border (fig. 5).
–
Introduce
and
place
the
cook-top
in
the
hole
made
in
the
piece
of
furniture,
then
fasten
it
with
the
screws
and
fastening
brackets
supplied
(fig.6).
WARNING
: Failure to fix the cooktop to the bench
could
result
in
loosening
of
the
gas
connection
through movement of the cooktop and a gas leak
may result.
A
duplicate
rating
label
is
included
with
these
instructions.
Ensure
this
is
attached
to
a
readily
accessible
surface,
so
that
the
cooktop
can
be
easily identified in the case of a service call.
INSTALLATION ROOM
This
appliance
is
not
provided
with
a
device
for
exhausting the products of combustion.
Therefore,
it
is
necessary
to
discharge
these
outside.
The
room
where
this
appliance
is
installed
must
have
a
natural
air
inflow,
so
as
to
ensure
a
regular
gas
combustion
and
room
ventilation:
the
necessary
air
volume
must
not
be
lower
than
20m
3
.
Air must come from permanent openings made on
the room walls that communicate with the outside.
The section of these openings shall correspond to
at least 200 cm
2
.
OPERATION ON N.G.
Regulator
An
appliance
regulator
is
provided. The
regulator
must be positioned so that the pressure test nipple
is
accessible
when
the
appliance
is
installed.
Connect the gas supply to the 1/2" B.S.P. internal
thread
inlet
of
the
regulator.
Refer
to
page
8
for
connection point position.
Regulators
are
supplied
pre-adjusted
and