13
Bell
fi res
Installation instructions
CLEARANCES
Figure 1: Clearances to combustible material
Clearance to non-combustible material
Always place a non-combustible insulation plate, at least ½
" (12 mm) thick between
the appliance and a non-combustible rear and side wall. Maintain a free space of at
least ¾" (2 cm) on either side of the insulation plate.
Minimum clearances as shown in fi gure 2 must be maintained.
&RPEXVWLEOHPDWHULDO
0DWqULHOFRPEXVWLEOHV
,QVXODWLRQERDUG
3DQQHDXGLVRODWLRQ
$SSOLDQFH
$SSDUHLO
1RQFRPEXVWLEOHPDWHULDO
0DWqULHOLQFRPEXVWLEOHV
,QVXODWLRQERDUG
3DQQHDXGLVRODWLRQ
$SSOLDQFH
$SSHUHLO
Figure 2: Clearances to non-combustible material
Ventilation
Ventilate the fi replace/chimney breast:
• all spaces between the appliance and the insulation plates
• all spaces between the insulation plates an all surrounding walls
by allowing vents above and below.