background image

6

Bellfires

English

Instructions for use and installation instructions

Summary of Contents for Corner Bell Large

Page 1: ...s fires with closed combustion system Bellfires wishes you many cosy evenings with your new Bellfires gas fire This document is an essential part of your gas fire Read it carefully before installation...

Page 2: ...psham Topsham Tunnel York Kent Retro Bell Large Retro Bell Intermediate Retro Bell Small Retro Bell Solo View Bell Corner Bell Large Corner Bell Small Horizon Bell XL Horizon Bell Large Horizon Bell L...

Page 3: ...4 Bellfires English Instructions for use and installation instructions...

Page 4: ...ons CONTENTS 1 WARRANTY TERMS 2 INSTRUCTIONS FOR USE 3 INSTALLATION INSTRUCTIONS 4 MAINTENANCE 5 FAULTS 6 ELECTRICAL DIAGRAM 7 DIMENSIONS 8 TECHNICAL DETAILS REGULATIONS 9 REPLACEMENT PARTS LIST 10 DI...

Page 5: ...6 Bellfires English Instructions for use and installation instructions...

Page 6: ...llowing aspects are not covered under the terms of the warranty defects arising which are attributable in whole or in part to a Not paying due heed to installation operating and maintenance instructio...

Page 7: ...8 Bellfires English Instructions for use and installation instructions...

Page 8: ...can burn at all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation It is essential that the...

Page 9: ...the front of your gas fire or outside the gas fire in a special box supplied If the control knob is fitted to the front of the gas fire the gas fire frame must be removed to access the knob The pilot...

Page 10: ...a few seconds before being extinguished 2 4 3 Extinguishing the pilot light You can extinguish the pilot light by pressing the control knob when it is in the PILOT position and turning it clockwise to...

Page 11: ...N mode after some time but you may immediately return to MAN by pressing the OFF button Set the current time l By simultaneously pressing and the display flashes You are in SET mode l Press to set the...

Page 12: ...DIP switches in the hand held transmitter l The DIP switches are concealed behind the battery holder in the hand held transmitter l Press the reset button on the receiver until a signal is heard l The...

Page 13: ...nition of the pilot light and main burner failed Possible cause air in the pilot light pipe Important If the pilot flame goes out then wait for at least 5 minutes before repeating the above procedure...

Page 14: ...mitter receiver batteries have a service life of approx one year We recommend you use alkaline batteries l The batteries must be replaced whenever 1 Hand held transmitter BATT appears in the display s...

Page 15: ...e fire l Switch the O I switch on the gas regulating block to the I position l Turn the motor knob on the gas regulating block as far as it will go in a clockwise direction The switch will audibly cli...

Page 16: ...coated with a lacquer layer resistant to high temperature During the first hours of operation the burning in of the lacquer may result in an unpleasant smell This is harmless however Operating the ga...

Page 17: ...ore cleaning Never use scouring powder aggressive cleaners or fire polish on the gas fire Use only a dry lint free cloth l Heat resistant lacquer in aerosols can be obtained from your distributor Duri...

Page 18: ...hrough the inner 100 mm pipe whereas the combustion air supply passes between the 100 mm and 150 mm pipes The gas fire can be installed in a completely sealed or mechanically ventilated house without...

Page 19: ...e 100 mm 150 mm systems can be used with either a newly built or existing chimney 3 3 PREPARATION FOR INSTALLATION The following preparation must be carried out before the gas fire can be installed 3...

Page 20: ...opening serving an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet...

Page 21: ...a facing wall 2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned op...

Page 22: ...mable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant material after assembly Ventilate the covered concent...

Page 23: ...m Horizon Bell Small tunnel 0 3 0 m 1 5 3 0 m Large tunnel XL Vertical Bell Small 0 0 6 m 0 5 1 0 m 0 3 0 m 1 0 3 0 m Vertical Bell Tunnel 0 1 6 m 0 0 1 0 m 0 3 0 m 1 0 3 0 m 1 4 23 10 11 12 13 23 X Y...

Page 24: ...end Appliance Distance Y min max All appliances except 2 0 11 0 m Jersey Vertical Bell Small 2 0 11 0 m Width B 30 mm Vertical Bell Tunnel Horizon Bell Medium 18 10 11 12 13 1 4 Y 28 16 17 16 24 23 24...

Page 25: ...istance Y1 Distance Y1 Y2 min max min max min max All appliances 0 3 0 m 1 0 10 0 m 1 0 10 0 m 16 23 Y2 X 10 11 12 13 14 15 Y1 4 1 28 23 23 17 24 Y1 Y2 X 2 1 vertical to horizontal ratio or 45 upwards...

Page 26: ...Vertical Bell Tunnel Horizon Bell Medium FLEXIBLE CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES Figure 12 Vertical chimney outlet using an existing lined chimney Flexible 100 mm and or...

Page 27: ...mm Y1 Y2 Y3 X 2 1 vertical to horizontal ratio or 45 upwards is always at least 2 to 1 Y2 Y1 10 11 12 13 45 X Y3 32 18 30 29 5 7 29 26 25 23 28 4 1 Appliance Distance X Distance Y1 Distance Y1 Y2 Y3 m...

Page 28: ...ney liners are present Flexible 100 mm 150 mm Appliance Distance Y min max All appliances except 2 0 11 0 m Jersey Vertical Bell Small 2 0 11 0 m Width B 30 mm Vertical Bell Tunnel Horizon Bell Medium...

Page 29: ...himney or when the chimney is unlined with a bend 45o Flexible 100 mm 150 mm Y1 Y2 Y3 X 2 1 vertical to horizontal ratio or 45 upwards is always at least 2 to 1 Appliance Distance X Distance Y1 Distan...

Page 30: ...ITIES REAR CONNECTION Figure 16 Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION 4 2 28 10 12 13 14 15 23 19 X 1 Y X 2 23 10 11 12 13 Appliance Distance X 1 Dis...

Page 31: ...POSSIBILITIES Appliance Distance X Distance Y min max min max Smart Bell 0 0 5 m 2 0 12 0 m REAR CONNECTION 2 4 28 10 12 13 14 15 23 10 11 12 13 17 16 18 23 24 24 16 X Y Figure 17 Vertical roof mounte...

Page 32: ...OOF OR WALL TERMINATION Figure 18 Vertical roof mounted outlet with bend SMART BELL RIGID CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTION Appliance Distance X1 Distance X...

Page 33: ...0 mm 150 mm and or rigid 100 mm 150 mm 32 31 29 29 30 18 4 2 28 10 12 13 14 15 6 8 7 26 29 29 28 27 Y X SMART BELL FLEXIBLE CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES REAR CONNECTIO...

Page 34: ...vertical to horizontal ratio or 45 upwards is always at least 2 to 1 Figure 20 Vertical chimney outlet using an existing unsound lined chimney or when the chimney is unlined with a bend 45o Flexible 1...

Page 35: ...TRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES AND SNORKEL REAR CONNECTION ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Figure 21 Horizontal wall outlet Snorkel Appliance Dist...

Page 36: ...e length twin wall balanced flue pipe length 500 mm incl and Twin wall balanced flue elbow 90o incl and Twin wall balanced flue elbow 45o incl and Vertical roof termination kit length 1360 mm vertical...

Page 37: ...e with gauging orifice L 165 mm incl and 90 concentric bend with inspection p anel incl and Universal wall floor support 150 mm Snorkel wall outlet set for Smart Bell ART ORDER NO 302189 302278 302279...

Page 38: ...at a maximum of 50 cm from the left or right hand side of the appliance 3 4 5 Convection package connections When fitting a convection package consideration should be given to the openings at approxi...

Page 39: ...ance Only the top and sides may be fitted with a strip of white loose insulation wool heat resistant to 1000 C wid th 15 cm max to protect the wall Do not use fibreglass or Rockwool or any other sort...

Page 40: ...iance with operation in the separate operating unit built in or otherwise The control unit and piping are supplied separately flat packed Remove the decorative edging and door of the operating unit Fi...

Page 41: ...sing a number 9 fork spanner See figure 25 26 and Chapter 6 Remote control Gas regulating block and receiver in operating unit Figure 25 Remote control Gas regulating block and receiver in operating u...

Page 42: ...g block must be fitted Figure 26 Gas regulating block Remote control Tab 2 8 x 0 8 mm Connection piezo cable Hand Control Side inlet Inlet Pressure Tap Thermo Unit Connection Minimum Rate Adjustment S...

Page 43: ...control Gas regulating block in operating unit The photo below shows how the piping for a hand control gas regulating block must be fitted Microswitch Motor Knob Operating Knob Remote control Hand con...

Page 44: ...on package The brickwork must be built up around the hearth In connection with the hearth expanding during burning there must be at least 3 mm clearance on either side of the appliance Do not build up...

Page 45: ...onnection After connection of the gas supply check that all connections are completely gas tight using soapy water or a leak tester 3 5 5 Positioning the ceramic log set marble pebbles and ceramic sto...

Page 46: ...them evenly over the burner mat and the grate around the burner Note Small embers and their residue should not be scattered on the burner This can cause a blockage on the burner orifices Embers must n...

Page 47: ...Horizon Bell Small Horizon Bell Large Tunnel Corner Bell Large Group A York Topsham incl Sandur Kent Corner Bell Small Vertical Bell Large View Bell incl Sandur Panorama Retro Bell Small Retro Bell So...

Page 48: ...49 Bellfires English Instructions for use and installation instructions Group D Horizon Bell Extra Large Embers must not be placed next to the pilot light burner...

Page 49: ...F Horizon Bell Small Tunnel Position the logs as shown below Group E Topsham Tunnel Position the logs as shown below The photos show the situation from either side Embers must not be placed next to th...

Page 50: ...use and installation instructions Group G a Jersey Natural gas Group G b Jersey Propane Embers must not be placed next to the pilot light burner Embers must not be placed next to the pilot light burn...

Page 51: ...52 Bellfires English Instructions for use and installation instructions Group H a Vertical Bell Small Natural gas Embers must not be placed next to the pilot light burner...

Page 52: ...3 Bellfires English Instructions for use and installation instructions Group H b Vertical Bell Small Propane Embers must not be placed next to the pilot light burner Keep the burner orifices unblocked...

Page 53: ...54 Bellfires English Instructions for use and installation instructions Group I Vertical Bell Tunnel Embers must not be placed next to the pilot light burner...

Page 54: ...55 Bellfires English Instructions for use and installation instructions Group J Smart Bell Logs must not be placed next to the pilot light burner...

Page 55: ...56 Bellfires English Instructions for use and installation instructions Group K a Horizon Bell Medium Natural gas Embers must not be placed next to the pilot light burner...

Page 56: ...7 Bellfires English Instructions for use and installation instructions Group K b Horizon Bell Medium Propane Keep the burner orifices unblocked Embers must not be placed next to the pilot light burner...

Page 57: ...ngs 2 Spread out the stones evenly on the bed of the burner Do not block the burner openings See separate notes for how to arrange the stones for the Jersey Vertical Bell Small Vertical Bell Tunnel an...

Page 58: ...59 Bellfires English Instructions for use and installation instructions Group B a Vertical Bell Small Natural gas Stones must not be placed next to the pilot light burner...

Page 59: ...60 Bellfires English Instructions for use and installation instructions Group B b Vertical Bell Small Propane Stones must not be placed next to the pilot light burner...

Page 60: ...for use and installation instructions Group C a Vertical Bell Tunnel Natural gas Group C b Vertical Bell Tunnel Propane Stones must not be placed next to the pilot light burner Stones must not be plac...

Page 61: ...62 Bellfires English Instructions for use and installation instructions Group D a Horizon Bell Medium Natural gas Stones must not be placed next to the pilot light burner...

Page 62: ...63 Bellfires English Instructions for use and installation instructions Group D b Horizon Bell Medium Propane Stones must not be placed next to the pilot light burner...

Page 63: ...ead the pebbles over the whole burner bed burner and grid around the burner Make sure that the pilot light remains free Figure 29 Marble pebbles set NATURAL GAS IMPORTANT Open area in order to ensure...

Page 64: ...frame until the wall has been finished Use the protective items supplied gloves or cloth Do not use masking tape 3 5 6 Mounting flue gas restriction plate Depending on the length and shape of the con...

Page 65: ...3 5 7 Checking the appliance following installation After installation visually check the gas flame When the fire is ignited the flames should be short and blue yellow in colour These flames should gr...

Page 66: ...nd or vermiculite granules set of logs and or pebbles on and around the main burner according to the installation directions in this instruction booklet Do not place any embers vermiculite granules lo...

Page 67: ...An incorrect flue gas restriction plate is fitted l The pilot light extinguishes if fumes are not exhausted or are insufficiently exhausted l The pilot light is either dirty or defective l Insufficien...

Page 68: ...ouple Ignition cable Antenna Button Reset Motor knob Operating Knob O I Switch Gas regulating block RECEIVER Battery Compartment panel 4 AA Batteries cable 2 cable 1 red black SPARK SPARK SW TC SW TC...

Page 69: ...installation instructions 7 1 DERBY DERBY II 7 DIMENSIONS Available with control unit in appliance bottom or in separate operating unit see page 82 Control unit in separate operating unit see page 82...

Page 70: ...71 Bellfires English Instructions for use and installation instructions 7 3 FLAT BELL 7 4 TOPSHAM...

Page 71: ...72 Bellfires English Instructions for use and installation instructions 7 6 YORK 7 5 TOPSHAM TUNNEL...

Page 72: ...73 Bellfires English Instructions for use and installation instructions 7 7 KENT 7 8 RETRO BELL LARGE...

Page 73: ...74 Bellfires English Instructions for use and installation instructions 7 10 RETRO BELL SMALL 7 9 RETRO BELL INTERMEDIATE...

Page 74: ...75 Bellfires English Instructions for use and installation instructions 7 11 RETRO BELL SOLO 7 12 VIEW BELL...

Page 75: ...76 Bellfires English Instructions for use and installation instructions 7 14 CORNER BELL SMALL 7 13 CORNER BELL LARGE...

Page 76: ...77 Bellfires English Instructions for use and installation instructions 7 15 HORIZON BELL EXTRA LARGE 7 16 HORIZON BELL LARGE...

Page 77: ...78 Bellfires English Instructions for use and installation instructions 7 18 HORIZON BELL MEDIUM 7 17 HORIZON BELL LARGE TUNNEL...

Page 78: ...79 Bellfires English Instructions for use and installation instructions 7 19 HORIZON BELL SMALL 7 20 HORIZON BELL SMALL TUNNEL...

Page 79: ...80 Bellfires English Instructions for use and installation instructions 7 22 VERTICAL BELL LARGE TUNNEL 7 21 VERTICAL BELL LARGE...

Page 80: ...81 Bellfires English Instructions for use and installation instructions 7 23 VERTICAL BELL SMALL 7 24 SMART BELL...

Page 81: ...82 Bellfires English Instructions for use and installation instructions OPERATING UNIT...

Page 82: ...ar 29 2 mbar Burner pressure max Cold 11 9 mbar 29 2 mbar Burner pressure min 2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik G...

Page 83: ...Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 18 0 mm 2x 25...

Page 84: ...as regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 12 0 mm 2x 25...

Page 85: ...Hot operating unit Burner pressure max 16 0 mbar 29 4 mbar Cold Burner pressure min 2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control M...

Page 86: ...rating unit Burner pressure max 8 0 mbar 29 2 mbar Cold Burner pressure min 2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV...

Page 87: ...ar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 1...

Page 88: ...mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 12 0 mm...

Page 89: ...5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 12 0...

Page 90: ...sure min 2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet m...

Page 91: ...n 2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main bur...

Page 92: ...2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burne...

Page 93: ...mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner 1x 12 0 mm...

Page 94: ...2 0 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burn...

Page 95: ...ar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP IGP Primary air inlet main burner min 3 mm max...

Page 96: ...12 302086 Cut off nipple 4 mm GV 34 GV 60 13 302067 Cable sw Receiver Thermocouple interrupter L 500 mm 14 302150 Switch with short length of cable to thermocouple interrupter and long length of cabl...

Page 97: ...2 1 3 311880 2 1 3 311883 1 1 2 2 311883 1 1 1 2 311879 1 1 2 311884 2 1 3 311879 1 1 2 311879 1 1 2 311883 1 1 1 2 311883 1 1 1 2 311879 1 1 2 311879 1 1 2 311879 1 1 2 311880 2 2 4 311879 1 1 2 311...

Page 98: ...g This can include Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be dispos...

Page 99: ...01 010307 311813 INTERFOCOS B V HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E mail info interfocos nl Internet www interfocos com...

Reviews: