Electrical connections diagram for multiple parallel panels
(more entrances in a building)
EN
8
4.6
EN
To one or
more families
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPA1 (address 1)
110Va.c.
230Va.c.
+U C/D GND Vin
VPA2 (address 2)
+U C/D GND Vin
+U C/D GND Vin
+U C/D GND Vin
110Va.c.
230Va.c.
110Va.c.
230Va.c.
110Va.c.
230Va.c.
OUT 1
C/D
GND
Vout
+U C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
SCU1
SCU2
SCU3
SCU4
VSB
OUT 1
OUT 1
OUT 1
1
2
3
4
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPA3 (address 3)
VPA4 (address 4)
Important:
One
VPA
outdoor panel and one
SCU
central unit will be mounted at each entrance.
The
VPA1 panel
keeps
address 1
, which is set from the factory.
The
VPA2 panel
with
address 2
Long press the
PROG.
button at
SCU 2
Long touch the
Fam.1
key at the
VPA2
panel.
long beep Short touch the
Fam.1
key, twice
Two short beeps
confirmation.
The
VPA3 panel
with
address 3
Long press the
PROG.
button at
SCU 3
Long touch the Fam.1 key at the
VPA3
panel.
long beep Short touch the Fam.1 key, three times
Three short beeps
confirmation.
The
VPA4 panel
with
address 4
Long press the
PROG.
button at
SCU 4
Long touch the Fam.1 key at the
VPA4
panel.
long beep Short touch the
Fam.1
key, four times
Four short beeps
confirmation.
Not
e
:
After the beep confirmation of the new address in the panel, go to the SCU of the panel and short press the
PROG.
button. The programming of the address is finished.
The programming of the addresses for the panels connected in parallel is done as follows:
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5