background image

EN

10

2. 

To delete the RFID access tags/cards from the memory of the panel:

- Long touch the 

Fam. 1

 key until the acoustic confirmation of the panel with a long beep.

- Short touch the 

Fam. 1

 key 7 times. The panel issues two short confirmation beeps.

- Immediately after, long touch (2-3 sec.) the 

Fam. 1

 key. All the codes of the RFID access tags/cards are deleted

permanently. The action is acoustically confirmed by a long beep.

3.

 Go to the place where the 

SCU

 central unit of the installation is mounted. Short press the 

PROG

 button on the 

SCU

The Red LED turns off. The installation returns to normal functioning mode.

4.

 Optional: From the outdoor panel, check if the old RFID tags/cards grant access. When each RFID tag/card that has

been deleted from the memory is approached to the panel, a low frequency beep will be issued. 
 

Adding a new RFID access TAG/CARD in the panel

   

 This procedure applies when you wish to 

add new RFID access tags/cards

 in the outdoor panel.

1.

 Collect all the RFID tags/cards from all the people who have access in the building and prepare the new access

tags/cards.

2.

 First, follow the procedure described in 

chapter 5.2

 for deleting all the tags/cards from the memory of the panel.

3.

 Follow the procedure described in 

chapter 5.1

. In this case, when you perform 

point 2

 of 

chapter 5.1

, it is mandatory

to approach both the new access tags/cards, and the old tags/cards to the RFID area of the panel, 

for reprogramming. 

4.

 After performing 

point 3

 of 

chapter 5.1

, check if access is granted for all the programmed and reprogrammed

RFID access tags/cards.

The 

Touch Line

 audio-video terminals must be kept away from water, lime or any liquid substances, blows, fumes, powders,

dust etc.     

For cleaning the glass screens, use a clean cloth and a special solution for glass washing.     

In case of renovation activities, the entire surface of the panels will be protected with plastic foil.    

DO NOT undo the electrical connections of the video door phone installation components.    

DO NOT short-circuit the electrical connections of the video door phone installation components.

a.

 Warranty is granted according to the current legislation in the buyer's country of residence, based on the purchase documents.

b.

 Warranty is granted for the hidden defects of the components used in production and in case of the system not functioning

according to the present user manual.

WARRANTY IS NOT GRANTED FOR:

c.

 Inappropriate installation and use.

d.

 Deterioration, intentional blows.

e.

 Unauthorized interventions to any of the components of the installation

f.

  Theft, fire, natural disasters

g.

 Lack of protection of the installation components in case of renovation activities.

6

Maintenance of the video outdoor panels

7

Warranty

5.3

EN

EN

EN

Summary of Contents for VPA.1FR02

Page 1: ...VIDEO OUTDOOR PANELS 1 5 Families for TL door phone systems User manual 4 wires 1 Fam Video 2 Fam Video 3 Fam Video 5 Fam Video EN ...

Page 2: ...H x 597 V 800 TVL video 1 Vpp 75 W PAL 70º 25º orientable video camera Case aluminum 4 mm chemicallytoughened glass IR LEDs 850 nm IR CUT for night vision 10m TOUCH keys for call and family name backlighted during night Access RFID card Access RFID card Wall mounting height 160 cm 1 52 kg EN EN Any intervention on the installation must be performed byAUTHORIZED PERSONNEL DO NOT power the product a...

Page 3: ...itoring and video recording from the panel Settings Programming Programming and deletion of RFID building access tags cards Programming of new address 2 3 or 4 for parallel connected panels in case of buildings with multiple entrances maximum 4 outdoor panels for one building Enabling or disabling of video monitoring signaling Red LED ON OFF through the JP1 RED LED 0 ch 4 1 step 4 Enabling or disa...

Page 4: ...5 o 25 o 25 o 30 o 30 EN 3 5 cm 20 cm 20 cm 1 5 cm Mount back the family name module Signaling of video monitoring JP1 on RED LED position No video monitoring signaling JP1 on 0 position Mounting on the wall Surface Unmount the module and add name labels EN STEP 2 STEP 3 STEP 4 STEP 5 JP1 RED LED 0 o 70 0 JP2 DVR DVR JP 2 0 Video camera angle adjustment The video camera will be oriented towards th...

Page 5: ...ons in the panel Torx Mounting the outdoor panel on the wall Surface Important For both types of mounting the Torx screws for fastening the outdoor panels on the wall will be very well tightened to prevent the anti theft alarm sensor from setting off U C D GND Vout U C D GND Vout 4 2 EN STEP 1 STEP 1 1 EN 4 ...

Page 6: ...GNG 2 GNG 1 DBL 1 DBL 2 Doorbell GONG Fam 1 address 1 U C D GND Vin Note2 Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional terminals mounted in parallel will have the address of the main terminal For Fam 2 the terminal will be programmed with address 2 See Ch 6 of the user manual for TL audio video terminals Note1 For r...

Page 7: ... Fam 3 Note For residences with 3 families and one entrance entrance 1 the outdoor panel has address 1 which is set by the producer For multiple entrances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 Note Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional termin...

Page 8: ...ances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 VPA address 1 GONG GONG GONG GONG Vcam U GND Vin2 110Va c 50Hz 60Hz 230Va c 50Hz 60Hz U C D GND Vin SCU OUT1 U PROG BAT 110 230V SWC 1 SWC 2 SWC LC 1 LC 2 LCK AUX 1 AUX 2 LA 1 LA 2 LS 1 LS 2 AUX L N 2x6Aa c OUT2 U C D GND Vout U C D GND Vout Doorbell GNG 2 GNG 1 DBL 1 DBL 2 U C D GND Vin...

Page 9: ... Long press the PROG button at SCU 2 Long touch the Fam 1 keyat the VPA2 panel long beep Short touch the Fam 1 key twice Two short beeps confirmation The VPA3 panel with address 3 Long press the PROG button at SCU 3 Long touch the Fam 1 keyat the VPA3 panel long beep Short touch the Fam 1 key three times Three short beeps confirmation The VPA4 panel with address 4 Long press the PROG button at SCU 4...

Page 10: ...in the outdoor panel During programming the installation has to be connected to the grid 110V 230Va c and fully operational 1 Go to the place where the SCU central unit of the installation is mounted Long press 3 sec the PROG button on the SCU The Red LED turns on 2 Take the RFID tags cards to the outdoor panels To program them approach every tag card for one second to the RFID area of the outdoor...

Page 11: ...e when you perform point 2 of chapter 5 1 it is mandatory to approach both the new access tags cards and the old tags cards to the RFID area of the panel for reprogramming 4 After performing point 3 of chapter 5 1 check if access is granted for all the programmed and reprogrammed RFID access tags cards The Touch Line audio video terminals must be kept away from water lime or any liquid substances ...

Page 12: ...f ELECTRA Group No 1732510 MPI Ciudad de Mexico Mexico ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante Spain BELLCOME ELECTRA products are registered as Industrial Models at EUIPO Alicante Spain The products are CE certified Certificate no E307311 ISO 9001 2008 ISO 14001 2009 Certificates no 73 100 4856 73 104 4856 by TÜV HESSEN The products are manufactured under Quality and Envi...

Reviews: