Use of the Video Outdoor Panels

            1. STAND-BY: 

The call keys with the name of the residents are permanently backlighted during night. The Red LED 

            blinks permanently.

2. CALL: 

Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaled

with a ding-dong. Each touch of the key reinitiates the call. 

4. 

END OF TALK:

 

- After 1 min. from the call, if the resident does not answer.

                            

- At 10 sec. after the door/gate is opened.

                            

- Immediately, if the resident decides to end the talk without opening the door/gate.

3. TALK: 

If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.

5. ACCESS: 

The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting is

acoustically signaled through a confirmation beep sequence.

    

6. RFID TAG/CARD ACCESS: 

If you program the RFID tags/cards in the outdoor panel, each resident of the building has

access using the secured RFID tag/card from BELLCOME. Approach the tag/card to the RFID         area marked on the

outdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the        

symbol blinks white.      

EN

9

Manual programming of the RFID TAGs/CARDs in the panel

At the moment of the delivery from the factory, the 

TL

 video outdoor panels do not have access tags/cards memorized.

In order to have access in the building after installation, it is mandatory to program the RFID tags/cards in the

outdoor panel. 

During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.

1.

 Go to the place where the 

SCU

 central unit of the installation is mounted. Long press (3 sec.) the 

PROG

 button on 

the 

SCU

. The Red LED turns on.

2. 

Take the RFID tags/cards to the outdoor panels. To program them, approach every tag/card for one second to the 

RFID        area of the outdoor panel. For each programmed tag/card, the panel issues two short beeps. Repeat this step 

for programming all the RFID tags/cards.

3. 

Go to the place where the 

SCU

 central unit of the installation is mounted. Short press the 

PROG

 button on the 

SCU

The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode.

                           

Orientable

 video camera

RFID reader. 

RFID tag/card access

Microphone

Fastening

 Torx screw

IR LEDs

(

night lighting

)

 

Touch keys 

for call, 

with the name of the residents

Speaker 

Fastening

 Torx screw

1 Fam.

5 Fam.

2 Fam., 3 Fam. 

Fam 2
Fam 1

Fam 3

Fam 4

Fam 5

Fam 1

29

mm

27

mm

115 mm

145 mm

5

EN

Deleting the RFID access TAGs/CARDs from the panel

5.2

EN

This procedure applies when you wish to 

give up access with RFID tags/cards

. During the deletion of the 

RFID

tags/cards

, the installation has to be connected to the grid (110V/230Va.c.) and fully operational.

1. 

Go to the place where the 

SCU

 central unit of the installation is mounted. Long press (3 sec.) the 

PROG

 button on

the 

SCU

. The Red LED turns on. The installation enters programming mode:

   

         

Not

e

:

 The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the

name labels are added. 

5.1

EN

Summary of Contents for VPA.1FR02

Page 1: ...VIDEO OUTDOOR PANELS 1 5 Families for TL door phone systems User manual 4 wires 1 Fam Video 2 Fam Video 3 Fam Video 5 Fam Video EN ...

Page 2: ...H x 597 V 800 TVL video 1 Vpp 75 W PAL 70º 25º orientable video camera Case aluminum 4 mm chemicallytoughened glass IR LEDs 850 nm IR CUT for night vision 10m TOUCH keys for call and family name backlighted during night Access RFID card Access RFID card Wall mounting height 160 cm 1 52 kg EN EN Any intervention on the installation must be performed byAUTHORIZED PERSONNEL DO NOT power the product a...

Page 3: ...itoring and video recording from the panel Settings Programming Programming and deletion of RFID building access tags cards Programming of new address 2 3 or 4 for parallel connected panels in case of buildings with multiple entrances maximum 4 outdoor panels for one building Enabling or disabling of video monitoring signaling Red LED ON OFF through the JP1 RED LED 0 ch 4 1 step 4 Enabling or disa...

Page 4: ...5 o 25 o 25 o 30 o 30 EN 3 5 cm 20 cm 20 cm 1 5 cm Mount back the family name module Signaling of video monitoring JP1 on RED LED position No video monitoring signaling JP1 on 0 position Mounting on the wall Surface Unmount the module and add name labels EN STEP 2 STEP 3 STEP 4 STEP 5 JP1 RED LED 0 o 70 0 JP2 DVR DVR JP 2 0 Video camera angle adjustment The video camera will be oriented towards th...

Page 5: ...ons in the panel Torx Mounting the outdoor panel on the wall Surface Important For both types of mounting the Torx screws for fastening the outdoor panels on the wall will be very well tightened to prevent the anti theft alarm sensor from setting off U C D GND Vout U C D GND Vout 4 2 EN STEP 1 STEP 1 1 EN 4 ...

Page 6: ...GNG 2 GNG 1 DBL 1 DBL 2 Doorbell GONG Fam 1 address 1 U C D GND Vin Note2 Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional terminals mounted in parallel will have the address of the main terminal For Fam 2 the terminal will be programmed with address 2 See Ch 6 of the user manual for TL audio video terminals Note1 For r...

Page 7: ... Fam 3 Note For residences with 3 families and one entrance entrance 1 the outdoor panel has address 1 which is set by the producer For multiple entrances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 Note Any type of TL terminal can be mounted indoors For Fam 1 the terminal has address 1 which is set by the producer The additional termin...

Page 8: ...ances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 VPA address 1 GONG GONG GONG GONG Vcam U GND Vin2 110Va c 50Hz 60Hz 230Va c 50Hz 60Hz U C D GND Vin SCU OUT1 U PROG BAT 110 230V SWC 1 SWC 2 SWC LC 1 LC 2 LCK AUX 1 AUX 2 LA 1 LA 2 LS 1 LS 2 AUX L N 2x6Aa c OUT2 U C D GND Vout U C D GND Vout Doorbell GNG 2 GNG 1 DBL 1 DBL 2 U C D GND Vin...

Page 9: ... Long press the PROG button at SCU 2 Long touch the Fam 1 keyat the VPA2 panel long beep Short touch the Fam 1 key twice Two short beeps confirmation The VPA3 panel with address 3 Long press the PROG button at SCU 3 Long touch the Fam 1 keyat the VPA3 panel long beep Short touch the Fam 1 key three times Three short beeps confirmation The VPA4 panel with address 4 Long press the PROG button at SCU 4...

Page 10: ...in the outdoor panel During programming the installation has to be connected to the grid 110V 230Va c and fully operational 1 Go to the place where the SCU central unit of the installation is mounted Long press 3 sec the PROG button on the SCU The Red LED turns on 2 Take the RFID tags cards to the outdoor panels To program them approach every tag card for one second to the RFID area of the outdoor...

Page 11: ...e when you perform point 2 of chapter 5 1 it is mandatory to approach both the new access tags cards and the old tags cards to the RFID area of the panel for reprogramming 4 After performing point 3 of chapter 5 1 check if access is granted for all the programmed and reprogrammed RFID access tags cards The Touch Line audio video terminals must be kept away from water lime or any liquid substances ...

Page 12: ...f ELECTRA Group No 1732510 MPI Ciudad de Mexico Mexico ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante Spain BELLCOME ELECTRA products are registered as Industrial Models at EUIPO Alicante Spain The products are CE certified Certificate no E307311 ISO 9001 2008 ISO 14001 2009 Certificates no 73 100 4856 73 104 4856 by TÜV HESSEN The products are manufactured under Quality and Envi...

Reviews: