14/17
The system functions
(Supply control unit
with accumulator)
The accumulator is
in charging mode
9
ok
8
At a repeated
monitoring
command on any
video Terminal
installed, the image
disappears (black LCD
screen)
Connect the JP1 jumper.
Check that at a repeated
monitoring command,
the image on the
Terminal's screen
remains unchanged.
The system functions
(Supply control unit
with accumulator)
Defect accumulator
or discharged
10
The system functions
(Supply control unit
with accumulator)
Lack of tension from
the 230V AC network
The system
functions powered
by the accumulator
1
1
Replace the
accumulator
Check the 10A fuses
from the electrical panel
and the 1,6A Fuse 1
from the Supply control
unit input.
Check the continuity of
the supply cables.
7
USE
Do not hit the glass screen with hard objects!
If the front glass screen cracks, DO NOT touch the product!
7
.1
User safety instructions
The JP1 jumper on the
Supply control unit is
NOT
CONNECTED, at each
stroke of the
MONITORING key ,
the image on the
screen of the Terminal
will change from the
image sent by the
video Outdoor panel to
off screen (there is no
video signal
connected to the Vin2
input of the Supply
control unit)
Control unit:
S1: green
S2: green
PROG:
Control unit:
S1: intermittent red
– green
S2: green
PROG:
Control unit:
S1: intermittent red –
green
S2: green
PROG:
acoustic signal
Control unit:
S1: red
S2:
PROG:
During the call and/or
communication, the
image on the
Terminal's screen
presents horizontal or
oblique lines, fixed or
mobile (moar)
Control unit:
S1: green
S2: green
PROG:
7
Locate and remedy the
defect.
The wires connected
to the Vin / Vout and
GNV terminals are not
twisted until close to
the terminals (until
approx. 1 cm from the
terminals).
EN